Fix it
Electric well pump, pressure switch and tank: troubleshooting and fixes
Find what it is doing, start at step 1 under it, and follow the steps. The app asks the same steps one question at a time.
Checked against official sources. Not yet reviewed by a licensed professional or tested by us.
Read this first
The parts
- A: the pressure tank
- C: the pump
- D: the tap nearest the tank
- E: the priming plug on top of the pump
- G: the pipe from the well to the house
- H: the foot valve at the bottom of the pipe in the well
- L: the breaker for the pump, in the panel
- M: a GFCI outlet, with test and reset buttons
If it: No water at any tap
1. Is there water, smoke or sparks near it, a smell of hot insulation, or has anyone felt a shock? There's water on the floor, or it has been wet or flooded → go to 2. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock → go to 3. No. It's dry, and none of that → go to 4.
- Look at the floor where you would stand. Water that belongs there, like a sump pit, doesn't count. Water over the floor does.
- Look and sniff around it, without touching it.
- Ask if anyone felt a shock from it, even a mild tingle.
2. Stop. There's water on the floor, or it has been wet or flooded
3. Stop. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock
4. Could flood water have reached the well, the pump or the wiring to it? Yes, or I can't tell → go to 5. No. Flood water never got near it → go to 6.
- Think back over any flood or standing water near the well.
- From dry ground, look at the top of the well, and at the pressure tank and the switch if it has them.
- Don't climb down into a well pit to look.
- Look for mud, silt or a water line on them.
5. Stop. Yes, or I can't tell
6. When a tap is open, does the pump start? It doesn't run. No sound, or only a hum or a click → go to 7. It runs → go to 8.
- Open the tap nearest the tank, D, all the way.
- Give it a good while. A full tank has to drop before the pump starts.
- Stand by the pump, C, and listen for the motor running. Touch nothing.
- If the pump is down the well or in a pit, listen from the top. Don't climb in.
- Shut the tap when you have your answer.
7. Is its breaker on, and its fuse good? It's off, in the middle, or the fuse is blown → go to 9. It's on, and the fuse is good → go to 10. Can't check? → go to 11.
Careful: Live electricity.
- If the floor by the panel is wet, don't go to it. Choose that you can't check this.
- Stand on a dry spot, with dry hands.
- Open the panel door, L. Leave the cover behind it on.
- Find the handle or fuse for this machine, if it's labeled.
- Look for a handle at off, or just short of on, or a blown fuse.
8. Does air spit from the tap? It spits air → go to 12. It runs steady, just weak, or not at all → go to 13.
Careful: Live electricity.
- The pump's breaker, L, has to be on for this. Switch it on if you switched it off.
- Open the tap, D, all the way.
- Watch the water. Does it burst out in spurts, with air in it?
- Shut the tap when you have your answer.
- If the pump runs on with the tap shut, switch it off at its breaker, L.
9. Reset the breaker (L). Fixed → done. Not fixed → go to 14. Can't do it → go to 14.
Careful: Live electricity.
- If the floor by the panel is wet, don't go to it. Say you can't.
- Stand on a dry spot, with dry hands.
- If the handle is at off, push it to on.
- If it sits near the middle, push it firmly to off, then to on.
- For a blown fuse, turn off what's on that circuit and screw in a new fuse of the same size. Put nothing else in the holder.
- If it trips again, stand clear and leave it off.
10. If it plugs into an outlet with test and reset buttons, has that outlet tripped? It had tripped, it's wet, or the reset won't stay in → go to 15. It's fine, or there's no such outlet → go to 16.
Careful: Live electricity.
- Look at the outlet, M, without touching it.
- If the outlet is wet, leave it alone and choose that it had tripped.
- If it's dry, press its reset button with a dry finger.
- See if the button stays in.
11. If it plugs into an outlet with test and reset buttons, has that outlet tripped? It had tripped, it's wet, or the reset won't stay in → go to 17. It's fine, or there's no such outlet → go to 18.
Careful: Live electricity.
How: see step 10.
12. Tighten the joints on the pipe from the well (G). Fixed → done. Not fixed → go to 19. Can't do it → go to 19.
Careful: Live electricity, Pressure.
- This is for a pump at the top of the well. A pump down the well can't be done this way. Say you can't.
- Pump down in a pit? Don't climb in. Say you can't.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Tighten each hose clamp and threaded joint on the pipe from the well, G, and at the pump, C.
- Take out the priming plug, E, fill the pump with clean water, and put the plug back.
- With the tap still open, switch the breaker on, and let the pump run until water comes.
- If no water comes after a short while, switch it off again.
- When the water runs steady, shut the tap.
- Treat the water as unsafe until the well has been disinfected and tested.
13. Is the pump casing empty of water? It is not full of water → go to 20. There's no plug. The pump is down the well → go to 21. It is full, or I can't get to it → go to 22.
Careful: Live electricity, Pressure.
- No priming plug on top of the pump, E? It's down the well, and needs no priming. Stop here and say so.
- Pump down in a pit? Don't climb in. Say it's full.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Hot to a hand held near it? Let it cool first.
- Take out the priming plug, E, and look in.
- Is the water at the top?
- Put the plug back, and shut the tap. Leave the breaker off for now.
14. What's left: Something on this circuit keeps tripping it.
15. Reset the GFCI outlet (M). Fixed → done. Not fixed → go to 23. Can't do it → go to 23.
Careful: Live electricity.
- If the outlet is wet, leave it alone. Say you can't.
- Make sure your hands are dry.
- Press the reset button until it stays in.
- After an outage, press test, then reset. If test doesn't cut the power, the outlet has stopped protecting you. Unplug the machine and leave it.
- If it won't stay in, or trips again at once, leave it tripped. It's doing its job.
16. What's left: The motor or pump down the well has failed · The motor's overload has tripped, or the control box has failed · The pressure switch has failed.
17. Reset the GFCI outlet (M). Fixed → done. Not fixed → go to 24. Can't do it → go to 24.
Careful: Live electricity.
How: see step 15.
18. Reset the breaker (L). Fixed → done. Not fixed → go to 25. Can't do it → go to 25.
Careful: Live electricity.
How: see step 9.
19. What's left: The pump may be pulling air, not water.
20. Fill the pump with water (E). Fixed → done. Not fixed → go to 26. Can't do it → go to 26.
Careful: Live electricity, Pressure.
- A pump down the well has no priming plug and needs no priming. Say you can't.
- Pump down in a pit? Don't climb in. Say you can't.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Hot to a hand held near it? Let it cool first.
- Take out the priming plug on top of the pump, E.
- Fill the pump casing to the top with clean water, the kind you would drink.
- Put the plug back.
- With the tap still open, switch the breaker on, and let the pump run until water comes.
- If no water comes after a short while, switch it off again.
- When the water runs steady, shut the tap.
No spare? Only doubtful water to hand? Make it safe first, as you would to drink it. It goes into the line.
21. What's left: The fault is down the well.
22. What's left: The water in the well may be too low.
23. What's left: The GFCI outlet won't hold, or has failed.
24. What's left: The GFCI outlet won't hold, or has failed.
25. What's left: Something on this circuit keeps tripping it · The motor or pump down the well has failed · The motor's overload has tripped, or the control box has failed · The pressure switch has failed.
26. Tighten the joints on the pipe from the well (G). Fixed → done. Not fixed → go to 27. Can't do it → go to 27.
Careful: Live electricity, Pressure.
How: see step 12.
27. Look at the foot valve, and replace it if it is worn (H). Fixed → done. Not fixed → go to 28. Can't do it → go to 28.
Careful: Live electricity, Pressure, Heavy.
- A pump that hangs down the well on a cable can't be done this way. Say you can't.
- This opens the well. Once it's open, treat the water as unsafe until the well has been disinfected and tested.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Unjoin the pipe from the pump, and lift off the well cap.
- Get a second person. A full pipe is heavy, and it can slip back down the well.
- Draw the pipe up out of the well until the foot valve, H, is in your hands.
- Look at the valve and its seat for wear.
- Clean the seat, or put in a new valve.
- Wash the outside of the pipe as you lower it back. Join it to the pump, and put the well cap back.
- Take out the priming plug, E, fill the pump with clean water, and put the plug back.
- With the tap still open, switch the breaker on, and let the pump run until water comes.
- If no water comes after a short while, switch it off again.
- When the water runs steady, shut the tap.
- Treat the water as unsafe until the well has been disinfected and tested.
No spare? No new valve? Clean the old one and its seat, and put it back.
28. What's left: The pump is filled and run, and still brings no water.
If it: Low pressure, or air spits from the taps
1. Is there water, smoke or sparks near it, a smell of hot insulation, or has anyone felt a shock? There's water on the floor, or it has been wet or flooded → go to 2. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock → go to 3. No. It's dry, and none of that → go to 4.
- Look at the floor where you would stand. Water that belongs there, like a sump pit, doesn't count. Water over the floor does.
- Look and sniff around it, without touching it.
- Ask if anyone felt a shock from it, even a mild tingle.
2. Stop. There's water on the floor, or it has been wet or flooded
3. Stop. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock
4. Could flood water have reached the well, the pump or the wiring to it? Yes, or I can't tell → go to 5. No. Flood water never got near it → go to 6.
- Think back over any flood or standing water near the well.
- From dry ground, look at the top of the well, and at the pressure tank and the switch if it has them.
- Don't climb down into a well pit to look.
- Look for mud, silt or a water line on them.
5. Stop. Yes, or I can't tell
6. With every tap shut, does the pump keep running, or keep starting again? Yes, it runs on, or keeps starting → go to 7. No, it stops and stays stopped → go to 8.
Careful: Live electricity.
- Shut every tap in the house.
- Listen at the pump, C, for a good while. From the top, if it is down in a pit.
- If it runs on and on, or keeps starting, switch it off at its breaker, L.
7. Does air spit from the tap? It spits air → go to 9. It runs steady, just weak, or not at all → go to 10.
Careful: Live electricity.
- The pump's breaker, L, has to be on for this. Switch it on if you switched it off.
- Open the tap, D, all the way.
- Watch the water. Does it burst out in spurts, with air in it?
- Shut the tap when you have your answer.
- If the pump runs on with the tap shut, switch it off at its breaker, L.
8. What's left: The pressure tank has too much air, so it is air-bound · The pressure tank has too little air, so it is waterlogged.
9. Tighten the joints on the pipe from the well (G). Fixed → done. Not fixed → go to 11. Can't do it → go to 11.
Careful: Live electricity, Pressure.
- This is for a pump at the top of the well. A pump down the well can't be done this way. Say you can't.
- Pump down in a pit? Don't climb in. Say you can't.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Tighten each hose clamp and threaded joint on the pipe from the well, G, and at the pump, C.
- Take out the priming plug, E, fill the pump with clean water, and put the plug back.
- With the tap still open, switch the breaker on, and let the pump run until water comes.
- If no water comes after a short while, switch it off again.
- When the water runs steady, shut the tap.
- Treat the water as unsafe until the well has been disinfected and tested.
10. Is water leaking from a pipe, the tank or the pump? Something is wet or dripping → go to 12. Everything is dry → go to 13.
Careful: Live electricity.
- Switch the pump off at its breaker, L, first.
- Look along the pipes, G, from the well to the house.
- Look at the tank, A, and at the pump, C. From the top, if they are down in a pit.
- Look for wet ground, drips and wet joints.
- A few slow drops at the pump's shaft are normal on many pumps.
- Keep clear of any wet wiring.
11. What's left: The pump may be pulling air, not water.
12. Patch the leaking pipe (G). Fixed → done. Not fixed → go to 14. Can't do it → go to 14.
Careful: Live electricity, Pressure.
- A patch is only for a pipe you can reach. A leak in the tank, the body of the pump or a buried pipe can't be done this way. Say you can't.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Shut the valve nearest the leak, if there is one.
- Wrap the leak with sheet rubber.
- Put a clamp on each side of the leak and tighten both.
- Open any valve you shut, and shut the tap.
- Switch the breaker on, and watch the patch as the pressure comes up. If it sprays, switch the breaker off.
- Make a lasting repair as soon as you can.
- If the leak was in the pipe from the well, treat the water as unsafe until the well has been disinfected and tested.
No spare? No sheet rubber? Wrap layers of friction tape over the leak, well past each side of it.
13. Is the pump casing empty of water? It is not full of water → go to 15. There's no plug. The pump is down the well → go to 16. It is full, or I can't get to it → go to 17.
Careful: Live electricity, Pressure.
- No priming plug on top of the pump, E? It's down the well, and needs no priming. Stop here and say so.
- Pump down in a pit? Don't climb in. Say it's full.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Hot to a hand held near it? Let it cool first.
- Take out the priming plug, E, and look in.
- Is the water at the top?
- Put the plug back, and shut the tap. Leave the breaker off for now.
14. What's left: The leak can't be patched.
15. Fill the pump with water (E). Fixed → done. Not fixed → go to 18. Can't do it → go to 18.
Careful: Live electricity, Pressure.
- A pump down the well has no priming plug and needs no priming. Say you can't.
- Pump down in a pit? Don't climb in. Say you can't.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Hot to a hand held near it? Let it cool first.
- Take out the priming plug on top of the pump, E.
- Fill the pump casing to the top with clean water, the kind you would drink.
- Put the plug back.
- With the tap still open, switch the breaker on, and let the pump run until water comes.
- If no water comes after a short while, switch it off again.
- When the water runs steady, shut the tap.
No spare? Only doubtful water to hand? Make it safe first, as you would to drink it. It goes into the line.
16. What's left: The fault is down the well.
17. What's left: The water in the well may be too low.
18. Tighten the joints on the pipe from the well (G). Fixed → done. Not fixed → go to 19. Can't do it → go to 19.
Careful: Live electricity, Pressure.
How: see step 9.
19. Look at the foot valve, and replace it if it is worn (H). Fixed → done. Not fixed → go to 20. Can't do it → go to 20.
Careful: Live electricity, Pressure, Heavy.
- A pump that hangs down the well on a cable can't be done this way. Say you can't.
- This opens the well. Once it's open, treat the water as unsafe until the well has been disinfected and tested.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Unjoin the pipe from the pump, and lift off the well cap.
- Get a second person. A full pipe is heavy, and it can slip back down the well.
- Draw the pipe up out of the well until the foot valve, H, is in your hands.
- Look at the valve and its seat for wear.
- Clean the seat, or put in a new valve.
- Wash the outside of the pipe as you lower it back. Join it to the pump, and put the well cap back.
- Take out the priming plug, E, fill the pump with clean water, and put the plug back.
- With the tap still open, switch the breaker on, and let the pump run until water comes.
- If no water comes after a short while, switch it off again.
- When the water runs steady, shut the tap.
- Treat the water as unsafe until the well has been disinfected and tested.
No spare? No new valve? Clean the old one and its seat, and put it back.
20. What's left: The pump is filled and run, and still brings no water.
If it: The pump starts and stops over and over, or never stops
1. Is there water, smoke or sparks near it, a smell of hot insulation, or has anyone felt a shock? There's water on the floor, or it has been wet or flooded → go to 2. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock → go to 3. No. It's dry, and none of that → go to 4.
- Look at the floor where you would stand. Water that belongs there, like a sump pit, doesn't count. Water over the floor does.
- Look and sniff around it, without touching it.
- Ask if anyone felt a shock from it, even a mild tingle.
2. Stop. There's water on the floor, or it has been wet or flooded
3. Stop. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock
4. Could flood water have reached the well, the pump or the wiring to it? Yes, or I can't tell → go to 5. No. Flood water never got near it → go to 6.
- Think back over any flood or standing water near the well.
- From dry ground, look at the top of the well, and at the pressure tank and the switch if it has them.
- Don't climb down into a well pit to look.
- Look for mud, silt or a water line on them.
5. Stop. Yes, or I can't tell
6. With every tap shut, does the pump keep running, or keep starting again? Yes, it runs on, or keeps starting → go to 7. No, it stops and stays stopped → go to 8.
Careful: Live electricity.
- Shut every tap in the house.
- Listen at the pump, C, for a good while. From the top, if it is down in a pit.
- If it runs on and on, or keeps starting, switch it off at its breaker, L.
7. Does air spit from the tap? It spits air → go to 9. It runs steady, just weak, or not at all → go to 10.
Careful: Live electricity.
- The pump's breaker, L, has to be on for this. Switch it on if you switched it off.
- Open the tap, D, all the way.
- Watch the water. Does it burst out in spurts, with air in it?
- Shut the tap when you have your answer.
- If the pump runs on with the tap shut, switch it off at its breaker, L.
8. What's left: The pressure switch has failed · The pressure tank has too little air, so it is waterlogged.
9. Tighten the joints on the pipe from the well (G). Fixed → done. Not fixed → go to 11. Can't do it → go to 11.
Careful: Live electricity, Pressure.
- This is for a pump at the top of the well. A pump down the well can't be done this way. Say you can't.
- Pump down in a pit? Don't climb in. Say you can't.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Tighten each hose clamp and threaded joint on the pipe from the well, G, and at the pump, C.
- Take out the priming plug, E, fill the pump with clean water, and put the plug back.
- With the tap still open, switch the breaker on, and let the pump run until water comes.
- If no water comes after a short while, switch it off again.
- When the water runs steady, shut the tap.
- Treat the water as unsafe until the well has been disinfected and tested.
10. Is water leaking from a pipe, the tank or the pump? Something is wet or dripping → go to 12. Everything is dry → go to 13.
Careful: Live electricity.
- Switch the pump off at its breaker, L, first.
- Look along the pipes, G, from the well to the house.
- Look at the tank, A, and at the pump, C. From the top, if they are down in a pit.
- Look for wet ground, drips and wet joints.
- A few slow drops at the pump's shaft are normal on many pumps.
- Keep clear of any wet wiring.
11. What's left: The pump may be pulling air, not water.
12. Patch the leaking pipe (G). Fixed → done. Not fixed → go to 14. Can't do it → go to 14.
Careful: Live electricity, Pressure.
- A patch is only for a pipe you can reach. A leak in the tank, the body of the pump or a buried pipe can't be done this way. Say you can't.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Shut the valve nearest the leak, if there is one.
- Wrap the leak with sheet rubber.
- Put a clamp on each side of the leak and tighten both.
- Open any valve you shut, and shut the tap.
- Switch the breaker on, and watch the patch as the pressure comes up. If it sprays, switch the breaker off.
- Make a lasting repair as soon as you can.
- If the leak was in the pipe from the well, treat the water as unsafe until the well has been disinfected and tested.
No spare? No sheet rubber? Wrap layers of friction tape over the leak, well past each side of it.
13. Is the pump casing empty of water? It is not full of water → go to 15. There's no plug. The pump is down the well → go to 16. It is full, or I can't get to it → go to 17.
Careful: Live electricity, Pressure.
- No priming plug on top of the pump, E? It's down the well, and needs no priming. Stop here and say so.
- Pump down in a pit? Don't climb in. Say it's full.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Hot to a hand held near it? Let it cool first.
- Take out the priming plug, E, and look in.
- Is the water at the top?
- Put the plug back, and shut the tap. Leave the breaker off for now.
14. What's left: The leak can't be patched.
15. Fill the pump with water (E). Fixed → done. Not fixed → go to 18. Can't do it → go to 18.
Careful: Live electricity, Pressure.
- A pump down the well has no priming plug and needs no priming. Say you can't.
- Pump down in a pit? Don't climb in. Say you can't.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Hot to a hand held near it? Let it cool first.
- Take out the priming plug on top of the pump, E.
- Fill the pump casing to the top with clean water, the kind you would drink.
- Put the plug back.
- With the tap still open, switch the breaker on, and let the pump run until water comes.
- If no water comes after a short while, switch it off again.
- When the water runs steady, shut the tap.
No spare? Only doubtful water to hand? Make it safe first, as you would to drink it. It goes into the line.
16. What's left: The fault is down the well.
17. What's left: The water in the well may be too low · The pump will not stop.
18. Tighten the joints on the pipe from the well (G). Fixed → done. Not fixed → go to 19. Can't do it → go to 19.
Careful: Live electricity, Pressure.
How: see step 9.
19. Look at the foot valve, and replace it if it is worn (H). Fixed → done. Not fixed → go to 20. Can't do it → go to 20.
Careful: Live electricity, Pressure, Heavy.
- A pump that hangs down the well on a cable can't be done this way. Say you can't.
- This opens the well. Once it's open, treat the water as unsafe until the well has been disinfected and tested.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Unjoin the pipe from the pump, and lift off the well cap.
- Get a second person. A full pipe is heavy, and it can slip back down the well.
- Draw the pipe up out of the well until the foot valve, H, is in your hands.
- Look at the valve and its seat for wear.
- Clean the seat, or put in a new valve.
- Wash the outside of the pipe as you lower it back. Join it to the pump, and put the well cap back.
- Take out the priming plug, E, fill the pump with clean water, and put the plug back.
- With the tap still open, switch the breaker on, and let the pump run until water comes.
- If no water comes after a short while, switch it off again.
- When the water runs steady, shut the tap.
- Treat the water as unsafe until the well has been disinfected and tested.
No spare? No new valve? Clean the old one and its seat, and put it back.
20. What's left: The pump is filled and run, and still brings no water.
If it: Sand or dirt in the water
1. Is there water, smoke or sparks near it, a smell of hot insulation, or has anyone felt a shock? There's water on the floor, or it has been wet or flooded → go to 2. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock → go to 3. No. It's dry, and none of that → go to 4.
- Look at the floor where you would stand. Water that belongs there, like a sump pit, doesn't count. Water over the floor does.
- Look and sniff around it, without touching it.
- Ask if anyone felt a shock from it, even a mild tingle.
2. Stop. There's water on the floor, or it has been wet or flooded
3. Stop. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock
4. Could flood water have reached the well, the pump or the wiring to it? Yes, or I can't tell → go to 5. No. Flood water never got near it → go to 6.
- Think back over any flood or standing water near the well.
- From dry ground, look at the top of the well, and at the pressure tank and the switch if it has them.
- Don't climb down into a well pit to look.
- Look for mud, silt or a water line on them.
5. Stop. Yes, or I can't tell
6. What's left: The fault is down the well · The water in the well may be too low · Sand is coming up with the water and wearing the pump.
If it: The first run after the power was out
1. Is there water, smoke or sparks near it, a smell of hot insulation, or has anyone felt a shock? There's water on the floor, or it has been wet or flooded → go to 2. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock → go to 3. No. It's dry, and none of that → go to 4.
- Look at the floor where you would stand. Water that belongs there, like a sump pit, doesn't count. Water over the floor does.
- Look and sniff around it, without touching it.
- Ask if anyone felt a shock from it, even a mild tingle.
2. Stop. There's water on the floor, or it has been wet or flooded
3. Stop. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock
4. Could flood water have reached the well, the pump or the wiring to it? Yes, or I can't tell → go to 5. No. Flood water never got near it → go to 6.
- Think back over any flood or standing water near the well.
- From dry ground, look at the top of the well, and at the pressure tank and the switch if it has them.
- Don't climb down into a well pit to look.
- Look for mud, silt or a water line on them.
5. Stop. Yes, or I can't tell
6. When a tap is open, does the pump start? It doesn't run. No sound, or only a hum or a click → go to 7. It runs → go to 8.
- Open the tap nearest the tank, D, all the way.
- Give it a good while. A full tank has to drop before the pump starts.
- Stand by the pump, C, and listen for the motor running. Touch nothing.
- If the pump is down the well or in a pit, listen from the top. Don't climb in.
- Shut the tap when you have your answer.
7. Is its breaker on, and its fuse good? It's off, in the middle, or the fuse is blown → go to 9. It's on, and the fuse is good → go to 10. Can't check? → go to 11.
Careful: Live electricity.
- If the floor by the panel is wet, don't go to it. Choose that you can't check this.
- Stand on a dry spot, with dry hands.
- Open the panel door, L. Leave the cover behind it on.
- Find the handle or fuse for this machine, if it's labeled.
- Look for a handle at off, or just short of on, or a blown fuse.
8. Does air spit from the tap? It spits air → go to 12. It runs steady, just weak, or not at all → go to 13.
Careful: Live electricity.
- The pump's breaker, L, has to be on for this. Switch it on if you switched it off.
- Open the tap, D, all the way.
- Watch the water. Does it burst out in spurts, with air in it?
- Shut the tap when you have your answer.
- If the pump runs on with the tap shut, switch it off at its breaker, L.
9. Reset the breaker (L). Fixed → done. Not fixed → go to 14. Can't do it → go to 14.
Careful: Live electricity.
- If the floor by the panel is wet, don't go to it. Say you can't.
- Stand on a dry spot, with dry hands.
- If the handle is at off, push it to on.
- If it sits near the middle, push it firmly to off, then to on.
- For a blown fuse, turn off what's on that circuit and screw in a new fuse of the same size. Put nothing else in the holder.
- If it trips again, stand clear and leave it off.
10. If it plugs into an outlet with test and reset buttons, has that outlet tripped? It had tripped, it's wet, or the reset won't stay in → go to 15. It's fine, or there's no such outlet → go to 16.
Careful: Live electricity.
- Look at the outlet, M, without touching it.
- If the outlet is wet, leave it alone and choose that it had tripped.
- If it's dry, press its reset button with a dry finger.
- See if the button stays in.
11. If it plugs into an outlet with test and reset buttons, has that outlet tripped? It had tripped, it's wet, or the reset won't stay in → go to 17. It's fine, or there's no such outlet → go to 18.
Careful: Live electricity.
How: see step 10.
12. Tighten the joints on the pipe from the well (G). Fixed → done. Not fixed → go to 19. Can't do it → go to 19.
Careful: Live electricity, Pressure.
- This is for a pump at the top of the well. A pump down the well can't be done this way. Say you can't.
- Pump down in a pit? Don't climb in. Say you can't.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Tighten each hose clamp and threaded joint on the pipe from the well, G, and at the pump, C.
- Take out the priming plug, E, fill the pump with clean water, and put the plug back.
- With the tap still open, switch the breaker on, and let the pump run until water comes.
- If no water comes after a short while, switch it off again.
- When the water runs steady, shut the tap.
- Treat the water as unsafe until the well has been disinfected and tested.
13. Is the pump casing empty of water? It is not full of water → go to 20. There's no plug. The pump is down the well → go to 21. It is full, or I can't get to it → go to 22.
Careful: Live electricity, Pressure.
- No priming plug on top of the pump, E? It's down the well, and needs no priming. Stop here and say so.
- Pump down in a pit? Don't climb in. Say it's full.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Hot to a hand held near it? Let it cool first.
- Take out the priming plug, E, and look in.
- Is the water at the top?
- Put the plug back, and shut the tap. Leave the breaker off for now.
14. What's left: Something on this circuit keeps tripping it.
15. Reset the GFCI outlet (M). Fixed → done. Not fixed → go to 23. Can't do it → go to 23.
Careful: Live electricity.
- If the outlet is wet, leave it alone. Say you can't.
- Make sure your hands are dry.
- Press the reset button until it stays in.
- After an outage, press test, then reset. If test doesn't cut the power, the outlet has stopped protecting you. Unplug the machine and leave it.
- If it won't stay in, or trips again at once, leave it tripped. It's doing its job.
16. What's left: The motor's overload has tripped, or the control box has failed · The pressure switch has failed.
17. Reset the GFCI outlet (M). Fixed → done. Not fixed → go to 24. Can't do it → go to 24.
Careful: Live electricity.
How: see step 15.
18. Reset the breaker (L). Fixed → done. Not fixed → go to 25. Can't do it → go to 25.
Careful: Live electricity.
How: see step 9.
19. What's left: The pump may be pulling air, not water.
20. Fill the pump with water (E). Fixed → done. Not fixed → go to 26. Can't do it → go to 26.
Careful: Live electricity, Pressure.
- A pump down the well has no priming plug and needs no priming. Say you can't.
- Pump down in a pit? Don't climb in. Say you can't.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Hot to a hand held near it? Let it cool first.
- Take out the priming plug on top of the pump, E.
- Fill the pump casing to the top with clean water, the kind you would drink.
- Put the plug back.
- With the tap still open, switch the breaker on, and let the pump run until water comes.
- If no water comes after a short while, switch it off again.
- When the water runs steady, shut the tap.
No spare? Only doubtful water to hand? Make it safe first, as you would to drink it. It goes into the line.
21. What's left: The fault is down the well.
22. What's left: The water in the well may be too low.
23. What's left: The GFCI outlet won't hold, or has failed.
24. What's left: The GFCI outlet won't hold, or has failed.
25. What's left: Something on this circuit keeps tripping it · The motor's overload has tripped, or the control box has failed · The pressure switch has failed.
26. Tighten the joints on the pipe from the well (G). Fixed → done. Not fixed → go to 27. Can't do it → go to 27.
Careful: Live electricity, Pressure.
How: see step 12.
27. Look at the foot valve, and replace it if it is worn (H). Fixed → done. Not fixed → go to 28. Can't do it → go to 28.
Careful: Live electricity, Pressure, Heavy.
- A pump that hangs down the well on a cable can't be done this way. Say you can't.
- This opens the well. Once it's open, treat the water as unsafe until the well has been disinfected and tested.
- Switch the pump off at its breaker, L.
- Open the tap nearest the tank, D, all the way, and let it run until it stops. That lets the pressure out.
- If the pump starts, that was the wrong breaker. Switch off the right one before you go on.
- Unjoin the pipe from the pump, and lift off the well cap.
- Get a second person. A full pipe is heavy, and it can slip back down the well.
- Draw the pipe up out of the well until the foot valve, H, is in your hands.
- Look at the valve and its seat for wear.
- Clean the seat, or put in a new valve.
- Wash the outside of the pipe as you lower it back. Join it to the pump, and put the well cap back.
- Take out the priming plug, E, fill the pump with clean water, and put the plug back.
- With the tap still open, switch the breaker on, and let the pump run until water comes.
- If no water comes after a short while, switch it off again.
- When the water runs steady, shut the tap.
- Treat the water as unsafe until the well has been disinfected and tested.
No spare? No new valve? Clean the old one and its seat, and put it back.
28. What's left: The pump is filled and run, and still brings no water.
How to get by
Sources
- Keep Your Electric Water System in Service (REA leaflet PA-171), Pages 2-6
- Care of Your Electric Water System (REA leaflet), Pages 2-4
- Manual of Individual Water Supply Systems (EPA 570/9-82-004), Pumps; Storage, Pressure Tanks; Disinfection of Wells
- TM 5-661, Inspection and Preventive Maintenance Services for Water Supply Systems at Fixed Installations, Paragraphs 41, 43, 45 and 55
- FM 3-34.471 (FM 5-420), Plumbing, Pipe Fitting, and Sewerage, Chapter 11 Centrifugal Pumps, Paragraphs 11-8 to 11-11
- FM 3-34.471 (FM 5-420), Plumbing, Pipe Fitting, and Sewerage, chapters 3, 4 and 5, Paragraph 3-7
- Protect Your Home's Water (EPA Private Wells), Testing frequency
- Learn About Private Water Wells (EPA Private Wells), Well components
Open it in Minuteman. In the app it works with no signal.