Minuteman

Fix it

Sump pump: troubleshooting and fixes

Find what it is doing, start at step 1 under it, and follow the steps. The app asks the same steps one question at a time.

Checked against official sources. Not yet reviewed by a licensed professional or tested by us.

Read this first

The parts

  • L: the breaker or fuse at the panel
  • M: the GFCI outlet it plugs into
  • W: the pit, its cover and the pump

If it: The sump pump doesn't run

1. Is there water, smoke or sparks near it, a smell of hot insulation, or has anyone felt a shock? There's water on the floor, or it has been wet or flooded → go to 2. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock → go to 3. No. It's dry, and none of that → go to 4.

  • Look at the floor where you would stand. Water that belongs there, like a sump pit, doesn't count. Water over the floor does.
  • Look and sniff around it, without touching it.
  • Ask if anyone felt a shock from it, even a mild tingle.

2. Stop. There's water on the floor, or it has been wet or flooded

3. Stop. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock

4. Is its breaker on, and its fuse good? It's off, in the middle, or the fuse is blown → go to 5. It's on, and the fuse is good → go to 6. Can't check? → go to 7.

Careful: Live electricity.

  • If the floor by the panel is wet, don't go to it. Choose that you can't check this.
  • Stand on a dry spot, with dry hands.
  • Open the panel door, L. Leave the cover behind it on.
  • Find the handle or fuse for this machine, if it's labeled.
  • Look for a handle at off, or just short of on, or a blown fuse.

5. Reset the breaker (L). Fixed → done. Not fixed → go to 8. Can't do it → go to 8.

Careful: Live electricity.

  • If the floor by the panel is wet, don't go to it. Say you can't.
  • Stand on a dry spot, with dry hands.
  • If the handle is at off, push it to on.
  • If it sits near the middle, push it firmly to off, then to on.
  • For a blown fuse, turn off what's on that circuit and screw in a new fuse of the same size. Put nothing else in the holder.
  • If it trips again, stand clear and leave it off.

6. If it plugs into an outlet with test and reset buttons, has that outlet tripped? It had tripped, it's wet, or the reset won't stay in → go to 9. It's fine, or there's no such outlet → go to 10.

Careful: Live electricity.

  • Look at the outlet, M, without touching it.
  • If the outlet is wet, leave it alone and choose that it had tripped.
  • If it's dry, press its reset button with a dry finger.
  • See if the button stays in.

7. If it plugs into an outlet with test and reset buttons, has that outlet tripped? It had tripped, it's wet, or the reset won't stay in → go to 11. It's fine, or there's no such outlet → go to 12.

Careful: Live electricity.

How: see step 6.

8. What's left: Something on this circuit keeps tripping it.

9. Reset the GFCI outlet (M). Fixed → done. Not fixed → go to 13. Can't do it → go to 13.

Careful: Live electricity.

  • If the outlet is wet, leave it alone. Say you can't.
  • Make sure your hands are dry.
  • Press the reset button until it stays in.
  • After an outage, press test, then reset. If test doesn't cut the power, the outlet has stopped protecting you. Unplug the machine and leave it.
  • If it won't stay in, or trips again at once, leave it tripped. It's doing its job.

10. What's left: The backup battery has failed · The float that works the switch is stuck · Something has jammed the pump's impeller.

11. Reset the GFCI outlet (M). Fixed → done. Not fixed → go to 14. Can't do it → go to 14.

Careful: Live electricity.

How: see step 9.

12. Reset the breaker (L). Fixed → done. Not fixed → go to 15. Can't do it → go to 15.

Careful: Live electricity.

How: see step 5.

13. What's left: The GFCI outlet won't hold, or has failed.

14. What's left: The GFCI outlet won't hold, or has failed.

15. What's left: The backup battery has failed · Something on this circuit keeps tripping it · The float that works the switch is stuck · Something has jammed the pump's impeller.

If it: It runs, and the pit doesn't drop

1. Is there water, smoke or sparks near it, a smell of hot insulation, or has anyone felt a shock? There's water on the floor, or it has been wet or flooded → go to 2. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock → go to 3. No. It's dry, and none of that → go to 4.

  • Look at the floor where you would stand. Water that belongs there, like a sump pit, doesn't count. Water over the floor does.
  • Look and sniff around it, without touching it.
  • Ask if anyone felt a shock from it, even a mild tingle.

2. Stop. There's water on the floor, or it has been wet or flooded

3. Stop. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock

4. Clean the pit and the strainer (W). Fixed → done. Not fixed → go to 5. Can't do it → go to 5.

Careful: Live electricity.

  • A backup pump on a battery stays live with the breaker off. If this pump has one, don't put a hand in the pit. Say you can't.
  • Stand on a dry spot, with dry hands.
  • Break the electric circuit first. Turn off its breaker, L.
  • If it plugs in, pull the plug too.
  • Lift the pit cover, W.
  • Look for sludge or trash in the pit, and on the pump's strainer.
  • Lift the pump out only if you have to.
  • Clean the pit thoroughly, and the strainer.
  • Put it back. Plug it in if you unplugged it, turn the breaker on, and see if the pit drops.

5. What's left: A check valve on the discharge has jammed · The discharge line is frozen or blocked · Something has jammed the pump's impeller.

How to get by

Sources

  • TM 5-661, Inspection and Preventive Maintenance Services for Water Supply Systems at Fixed Installations, Paragraph 50
  • Utilitiesman 3, NAVEDTRA 125332, Chapter 5, Chapter 5, sump pumps
  • Floods (Ready.gov), Before a Flood
  • Basement Flood Mitigation (FEMA-1800-DR-IL handout), Check valves or backflow valves
  • CPSC Fact Sheet: What Is a GFCI? (Publication 099), Test every GFCI
  • CPSC Guide to Home Wiring Hazards (Publication 518), Fuses/Circuit Breakers, p. 13

Open it in Minuteman. In the app it works with no signal.