Minuteman

Fix it

Hand pump on a well: troubleshooting and fixes

Find what it is doing, start at step 1 under it, and follow the steps. The app asks the same steps one question at a time.

Checked against official sources. Not yet reviewed by a licensed professional or tested by us.

Read this first

The parts

  • A: the pump handle
  • B: the pump head, at the top of the pump
  • C: the spout
  • D: the pump rod, inside the pipe
  • E: the piston, with its cup seals

If it: No water comes when I pump

1. Could flood water have reached the well, the pump or the wiring to it? Yes, or I can't tell → go to 2. No. Flood water never got near it → go to 3.

  • Think back over any flood or standing water near the well.
  • From dry ground, look at the top of the well, and at the pressure tank and the switch if it has them.
  • Don't climb down into a well pit to look.
  • Look for mud, silt or a water line on them.

2. Stop. Yes, or I can't tell

3. How does the handle feel? It will not move → go to 4. It drops with no effort → go to 5. It moves with some push → go to 6.

  • Try the handle, A, gently, for a few strokes. Don't force it.
  • Does it refuse to move? Does it drop with nothing pushing back? Or does it move with some push?

4. What's left: The pump is frozen, or jammed.

5. What's left: The pump rod has broken or come loose from the piston.

6. Does water come, and does it stay ready? No water comes, or it takes many strokes each time → go to 7. Water comes right away → go to 8.

  • Work the handle, A, for a while, and watch the spout, C.
  • If water comes, stop for a short while.
  • Pump again. Does water come right away, or only after many strokes?

7. Prime the pump (B). Fixed → done. Not fixed → go to 9. Can't do it → go to 9.

  • A pump with a long rod down to a cylinder in the well has no priming to do. Say you can't.
  • Pour clean water, the kind you would drink, into the top of the pump head, B.
  • Work the handle, A, in full, quick strokes while you keep pouring.
  • Keep going until water comes from the spout, C.

No spare? Only doubtful water to hand? Make it safe first, as you would to drink it. It goes down toward the well.

8. Draw the piston up and look at the seals and valves (E). Fixed → done. Not fixed → go to 10. Can't do it → go to 10.

Careful: Heavy.

  • A pitcher pump, with its cylinder in the body and no rod down the pipe, can't be done this way. Say you can't.
  • This opens the well. Once it's open, treat the water as unsafe until the well has been disinfected and tested.
  • Disconnect the pump head, B, from the pipe.
  • Pull the pump rod, D, up with the piston, E, on its bottom end.
  • If it stops and won't come, the piston is too big for the pipe. Don't force it. Lower the rod, join the head back, and say you can't.
  • Look at the cup seals and at the valve in the piston.
  • Put on new cup seals. Clean any valve, or put in a new one.
  • Lower the rod and piston back, and join the pump head to the pipe.
  • Treat the water as unsafe until the well has been disinfected and tested.

No spare? No new seals? Put the old ones back if they are whole. The flow will stay weak.

9. Draw the piston up and look at the seals and valves (E). Fixed → done. Not fixed → go to 11. Can't do it → go to 11.

Careful: Heavy.

How: see step 8.

10. What's left: The cylinder may be worn.

11. What's left: The cylinder may be worn.

If it: The flow is weak

1. Could flood water have reached the well, the pump or the wiring to it? Yes, or I can't tell → go to 2. No. Flood water never got near it → go to 3.

  • Think back over any flood or standing water near the well.
  • From dry ground, look at the top of the well, and at the pressure tank and the switch if it has them.
  • Don't climb down into a well pit to look.
  • Look for mud, silt or a water line on them.

2. Stop. Yes, or I can't tell

3. Does grit come out with the water? Yes, there is sand or grit → go to 4. No, it is clean → go to 5.

  • Pump some water into a clear cup, held under the spout, C.
  • Let it stand a moment.
  • Look for sand or grit on the bottom.

4. What's left: Sand is wearing the cylinder and the cup seals.

5. Does water come, and does it stay ready? No water comes, or it takes many strokes each time → go to 6. Water comes right away → go to 7.

  • Work the handle, A, for a while, and watch the spout, C.
  • If water comes, stop for a short while.
  • Pump again. Does water come right away, or only after many strokes?

6. Prime the pump (B). Fixed → done. Not fixed → go to 8. Can't do it → go to 8.

  • A pump with a long rod down to a cylinder in the well has no priming to do. Say you can't.
  • Pour clean water, the kind you would drink, into the top of the pump head, B.
  • Work the handle, A, in full, quick strokes while you keep pouring.
  • Keep going until water comes from the spout, C.

No spare? Only doubtful water to hand? Make it safe first, as you would to drink it. It goes down toward the well.

7. Draw the piston up and look at the seals and valves (E). Fixed → done. Not fixed → go to 9. Can't do it → go to 9.

Careful: Heavy.

  • A pitcher pump, with its cylinder in the body and no rod down the pipe, can't be done this way. Say you can't.
  • This opens the well. Once it's open, treat the water as unsafe until the well has been disinfected and tested.
  • Disconnect the pump head, B, from the pipe.
  • Pull the pump rod, D, up with the piston, E, on its bottom end.
  • If it stops and won't come, the piston is too big for the pipe. Don't force it. Lower the rod, join the head back, and say you can't.
  • Look at the cup seals and at the valve in the piston.
  • Put on new cup seals. Clean any valve, or put in a new one.
  • Lower the rod and piston back, and join the pump head to the pipe.
  • Treat the water as unsafe until the well has been disinfected and tested.

No spare? No new seals? Put the old ones back if they are whole. The flow will stay weak.

8. Draw the piston up and look at the seals and valves (E). Fixed → done. Not fixed → go to 10. Can't do it → go to 10.

Careful: Heavy.

How: see step 7.

9. What's left: The cylinder may be worn.

10. What's left: The cylinder may be worn.

If it: The handle is loose, or goes down with no effort

1. Could flood water have reached the well, the pump or the wiring to it? Yes, or I can't tell → go to 2. No. Flood water never got near it → go to 3.

  • Think back over any flood or standing water near the well.
  • From dry ground, look at the top of the well, and at the pressure tank and the switch if it has them.
  • Don't climb down into a well pit to look.
  • Look for mud, silt or a water line on them.

2. Stop. Yes, or I can't tell

3. How does the handle feel? It will not move → go to 4. It drops with no effort → go to 5. It moves with some push → go to 6.

  • Try the handle, A, gently, for a few strokes. Don't force it.
  • Does it refuse to move? Does it drop with nothing pushing back? Or does it move with some push?

4. What's left: The pump is frozen, or jammed.

5. What's left: The pump rod has broken or come loose from the piston.

6. Does it still bring as much water as it used to? Yes, about the same → go to 7. No, less than it did → go to 8.

  • Work the handle, A, for a few strokes.
  • Watch the spout, C.

7. What's left: The handle's pivots are worn.

8. Draw the piston up and look at the seals and valves (E). Fixed → done. Not fixed → go to 9. Can't do it → go to 9.

Careful: Heavy.

  • A pitcher pump, with its cylinder in the body and no rod down the pipe, can't be done this way. Say you can't.
  • This opens the well. Once it's open, treat the water as unsafe until the well has been disinfected and tested.
  • Disconnect the pump head, B, from the pipe.
  • Pull the pump rod, D, up with the piston, E, on its bottom end.
  • If it stops and won't come, the piston is too big for the pipe. Don't force it. Lower the rod, join the head back, and say you can't.
  • Look at the cup seals and at the valve in the piston.
  • Put on new cup seals. Clean any valve, or put in a new one.
  • Lower the rod and piston back, and join the pump head to the pipe.
  • Treat the water as unsafe until the well has been disinfected and tested.

No spare? No new seals? Put the old ones back if they are whole. The flow will stay weak.

9. What's left: The cylinder may be worn.

If it: Sand in the water

1. Could flood water have reached the well, the pump or the wiring to it? Yes, or I can't tell → go to 2. No. Flood water never got near it → go to 3.

  • Think back over any flood or standing water near the well.
  • From dry ground, look at the top of the well, and at the pressure tank and the switch if it has them.
  • Don't climb down into a well pit to look.
  • Look for mud, silt or a water line on them.

2. Stop. Yes, or I can't tell

3. What's left: Sand is wearing the cylinder and the cup seals.

How to get by

Sources

  • Wells Construction: Hand Dug and Hand Drilled (Manual M-9), Appendix VII, hand pumps, Appendix VII, Introduction, pp. 262-267
  • Care of Your Electric Water System (REA leaflet), Page 3
  • TM 5-661, Inspection and Preventive Maintenance Services for Water Supply Systems at Fixed Installations, Paragraphs 41 and 44
  • Manual of Individual Water Supply Systems (EPA 570/9-82-004), Hand Pumps; Disinfection of Wells
  • Protect Your Home's Water (EPA Private Wells), Testing frequency

Open it in Minuteman. In the app it works with no signal.