Minuteman

Fix it

Furnace: troubleshooting and fixes

Find what it is doing, start at step 1 under it, and follow the steps. The app asks the same steps one question at a time.

Checked against official sources. Not yet reviewed by a licensed professional or tested by us.

Read this first

The parts

  • A: the thermostat on the wall
  • B: the furnace's own power switch
  • C: the gas control and its lighting label
  • D: the oil tank and its gage
  • E: the blower, behind its door, with its motor and belt
  • F: the air filter in its slot
  • H: the burner and its flame window
  • J: the gas meter and the valve beside it, outdoors
  • K: the valve on the oil line
  • L: the breaker or fuse at the panel
  • Q: the damper handles on the ducts
  • R: the oil burner's reset button
  • S: the drain tube of a high-efficiency furnace
  • T: the humidifier pan on the ducts

If it: No heat at all, and it burns gas

1. Do you smell gas in the house, or hear it hissing? Yes, I smell it or hear it → go to 2. No, I don't smell or hear gas → go to 3.

  • Notice any smell of gas as you walk in.
  • If you smell it, stop there and answer yes. Don't go on to the appliance.
  • If you smell nothing, listen near the appliance, without touching anything on it.
  • If the appliance is electric, answer for the house all the same.

2. Stop. Yes, I smell it or hear it

3. Is anyone feeling sick, or is a carbon monoxide alarm sounding? And look at the pipe that carries the furnace or boiler's smoke away. Someone feels sick, dizzy or weak, or an alarm is sounding → go to 4. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room → go to 5. None of that. Everyone's fine, and the pipe is whole → go to 6.

  • Ask everyone in the house if they feel sick, dizzy or weak.
  • Listen for a carbon monoxide alarm.
  • Notice any smoke or fumes coming into the room from the furnace or boiler.
  • Follow the metal pipe from the furnace or boiler to the chimney or the wall, by eye. Don't touch it. It can be hot.
  • Look for holes, spots rusted through, joints come apart, a gap, or a stretch that runs downhill.
  • Plastic vent pipes? Follow them to where they leave the house, and look that nothing blocks their ends outside.

4. Stop. Someone feels sick, dizzy or weak, or an alarm is sounding

5. Stop. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room

6. Has flood water reached it, up to its burner, or reached its ducts? Yes, or I can't tell → go to 7. No. Flood water never got near it → go to 8.

  • Think back over any flood in this room since it last ran.
  • Look low on it, where the burner sits, H, for a water line, mud or silt.
  • On a furnace, look at the ducts near the floor as well.

7. What's left: Flood water reached the burner or the ducts.

8. Since it last worked, has anyone smelled gas, or shut off the gas at the meter, outside, or at the valve on the pipe to it? Yes, or I'm not sure → go to 9. No → go to 10.

  • Ask everyone in the house. A smell from yesterday counts.
  • Ask if anyone turned the valve at the gas meter, J, a valve outside, or the valve on the pipe to it, or if the gas company did.
  • The knob on its own gas control, C, doesn't count. Its lighting label covers that one.

9. What's left: The gas was shut off, or someone smelled it.

10. Is the pilot flame burning? The pilot is out → go to 11. It's burning, it lights itself, or it has no pilot → go to 12. Can't check? → go to 13.

  • Smell for gas first. At any smell, stop here, leave the house, and go back to the first question.
  • Find the lighting label on the gas control, C, and the window by the burner, H.
  • Look for the small flame the label shows. A burner with no pilot has none to see.
  • If the label says the pilot or burner lights itself, or not to light it by hand, there is no pilot for you to light. Choose that.

11. Light the pilot by the label (C). Fixed → done. Not fixed → go to 14. Can't do it → go to 14.

  • Smell for gas first. At any smell, stop, do what the entry above says, and leave this burner alone.
  • Find the lighting label on the gas control, C. Read all of it first.
  • Follow only the steps on the label to light the pilot.
  • Look at the flame. It must wrap the tip of the thin metal rod beside it, the thermocouple.
  • If it won't light, or goes out again, choose that you can't do this one.

12. With the thermostat set warmer, does the burner light, and then does warm air blow? The burner doesn't light → go to 15. It lights, but no air blows, or it soon shuts off → go to 16. It lights, and warm air blows → go to 17. Can't check? → go to 18.

  • Smell for gas first. At any smell, stop, leave the house, and go back to the first question.
  • Set the thermostat, A, a few degrees warmer than the room.
  • Watch the burner's window, H, or listen for it to light.
  • Once it's lit, wait a few minutes, then hold a hand at a register in a room.

13. With the thermostat set warmer, does the burner light, and then does warm air blow? The burner doesn't light → go to 19. It lights, but no air blows, or it soon shuts off → go to 20. It lights, and warm air blows → go to 21. Can't check? → go to 22.

How: see step 12.

14. What's left: The pilot won't stay lit.

15. Do the lights work in the rest of the house? No, the power is out → go to 23. Yes, the lights work → go to 24.

  • Try a light in another room.
  • Try the light nearest it, if there is one.

16. Change or wash the air filter (F). Fixed → done. Not fixed → go to 25. Can't do it → go to 25.

Careful: Live electricity.

  • Turn its power switch, B, off, and wait for the blower to stop.
  • Filter behind the blower's door, E? Turn off its breaker, L, too, before you open the door, and leave the breaker panel's own cover on. Can't tell which breaker? Choose that you can't do this one.
  • Slide the filter out of its slot, F. Note which way its arrow points.
  • Hold it up to a light. If light comes through it easily, it's clean. Slide it back, close any door, turn the power back on, and choose that it didn't work.
  • Fit a new filter of the same size, with its arrow pointing the way the air flows, toward the blower.
  • A washable filter, wash it, let it dry, and spray it with filter adhesive as its can says before it goes back.
  • Close any door. Turn the breaker back on if you turned it off, then the switch.

No spare? No clean filter? The Navy's stopgap is to run without it until you have one. Put one back as soon as you can, because dust gets into the blower.

17. What's left: The thermostat's wiring or the burner's own controls.

18. Do the lights work in the rest of the house? No, the power is out → go to 26. Yes, the lights work → go to 27.

How: see step 15.

19. Do the lights work in the rest of the house? No, the power is out → go to 28. Yes, the lights work → go to 29.

How: see step 15.

20. Change or wash the air filter (F). Fixed → done. Not fixed → go to 30. Can't do it → go to 30.

Careful: Live electricity.

How: see step 16.

21. What's left: The thermostat's wiring or the burner's own controls.

22. Do the lights work in the rest of the house? No, the power is out → go to 31. Yes, the lights work → go to 32.

How: see step 15.

23. What's left: The house has no power.

24. Is its breaker on, and its fuse good? It's off, in the middle, or the fuse is blown → go to 33. It's on, and the fuse is good → go to 34. Can't check? → go to 35.

Careful: Live electricity.

  • If the floor by the panel is wet, don't go to it. Choose that you can't check this.
  • Stand on a dry spot, with dry hands.
  • Open the panel door, L. Leave the cover behind it on.
  • Find the handle or fuse for this machine, if it's labeled.
  • Look for a handle at off, or just short of on, or a blown fuse.

25. Let the blower motor cool and restart it (E). Fixed → done. Not fixed → go to 36. Can't do it → go to 36.

Careful: Live electricity.

  • Turn its power switch, B, off.
  • Can't tell which breaker at the panel feeds the furnace? Choose that you can't do this one.
  • Turn off its breaker, L, too, before you open anything. Leave the breaker panel's own cover on.
  • Open the blower's door, E, and let the motor cool.
  • Turn the blower wheel by hand. It should turn freely. If it binds or grinds, close the door and choose that you can't do this one.
  • If the motor has a reset button, press it once.
  • Close the door. Turn the breaker on, then the switch.
  • Listen for the blower when the burner is lit. If it stops again, turn the switch off and leave it off.

26. What's left: The house has no power.

27. Is its breaker on, and its fuse good? It's off, in the middle, or the fuse is blown → go to 37. It's on, and the fuse is good → go to 38. Can't check? → go to 39.

Careful: Live electricity.

How: see step 24.

28. What's left: The house has no power.

29. Is its breaker on, and its fuse good? It's off, in the middle, or the fuse is blown → go to 40. It's on, and the fuse is good → go to 41. Can't check? → go to 42.

Careful: Live electricity.

How: see step 24.

30. Let the blower motor cool and restart it (E). Fixed → done. Not fixed → go to 43. Can't do it → go to 43.

Careful: Live electricity.

How: see step 25.

31. What's left: The house has no power.

32. Is its breaker on, and its fuse good? It's off, in the middle, or the fuse is blown → go to 44. It's on, and the fuse is good → go to 45. Can't check? → go to 46.

Careful: Live electricity.

How: see step 24.

33. Reset the breaker (L). Fixed → done. Not fixed → go to 47. Can't do it → go to 47.

Careful: Live electricity.

  • If the floor by the panel is wet, don't go to it. Say you can't.
  • Stand on a dry spot, with dry hands.
  • If the handle is at off, push it to on.
  • If it sits near the middle, push it firmly to off, then to on.
  • For a blown fuse, turn off what's on that circuit and screw in a new fuse of the same size. Put nothing else in the holder.
  • If it trips again, stand clear and leave it off.

34. Set the thermostat warmer (A). Fixed → done. Not fixed → go to 48. Can't do it → go to 48.

  • Look at the thermostat, A. Already set to heat, and warmer than the room? Choose that it didn't work.
  • Set it to heat, the way its own instructions show.
  • Set it a few degrees warmer than the room.
  • Give it a few minutes. Listen for the burner to start.
  • Doesn't start? Choose that it didn't work.

35. Set the thermostat warmer (A). Fixed → done. Not fixed → go to 49. Can't do it → go to 49.

How: see step 34.

36. What's left: The blower's belt is broken or off · The blower, its motor or its control has failed.

37. Reset the breaker (L). Fixed → done. Not fixed → go to 50. Can't do it → go to 50.

Careful: Live electricity.

How: see step 33.

38. Change or wash the air filter (F). Fixed → done. Not fixed → go to 51. Can't do it → go to 51.

Careful: Live electricity.

How: see step 16.

39. Change or wash the air filter (F). Fixed → done. Not fixed → go to 52. Can't do it → go to 52.

Careful: Live electricity.

How: see step 16.

40. Reset the breaker (L). Fixed → done. Not fixed → go to 53. Can't do it → go to 53.

Careful: Live electricity.

How: see step 33.

41. Set the thermostat warmer (A). Fixed → done. Not fixed → go to 54. Can't do it → go to 54.

How: see step 34.

42. Set the thermostat warmer (A). Fixed → done. Not fixed → go to 55. Can't do it → go to 55.

How: see step 34.

43. What's left: The blower's belt is broken or off · The blower, its motor or its control has failed.

44. Reset the breaker (L). Fixed → done. Not fixed → go to 56. Can't do it → go to 56.

Careful: Live electricity.

How: see step 33.

45. Change or wash the air filter (F). Fixed → done. Not fixed → go to 57. Can't do it → go to 57.

Careful: Live electricity.

How: see step 16.

46. Change or wash the air filter (F). Fixed → done. Not fixed → go to 58. Can't do it → go to 58.

Careful: Live electricity.

How: see step 16.

47. What's left: Something on this circuit keeps tripping it.

48. Turn its power switch on (B). Fixed → done. Not fixed → go to 59. Can't do it → go to 59.

  • Find its own switch, B. It often looks like a light switch, on it, on the wall beside it, or at the top of the stairs.
  • Already on, or no switch to find? Choose that it didn't work.
  • Ask who turned it off, and why. If it was for a gas smell, smoke, water or a fault, leave it off and choose that you can't do this one.
  • Turn the switch on.
  • Give it a few minutes. Listen for the burner to start.
  • Doesn't start? Choose that it didn't work.

49. Turn its power switch on (B). Fixed → done. Not fixed → go to 60. Can't do it → go to 60.

How: see step 48.

50. What's left: Something on this circuit keeps tripping it.

51. Set the thermostat warmer (A). Fixed → done. Not fixed → go to 61. Can't do it → go to 61.

How: see step 34.

52. Set the thermostat warmer (A). Fixed → done. Not fixed → go to 62. Can't do it → go to 62.

How: see step 34.

53. What's left: Something on this circuit keeps tripping it.

54. Turn its power switch on (B). Fixed → done. Not fixed → go to 63. Can't do it → go to 63.

How: see step 48.

55. Turn its power switch on (B). Fixed → done. Not fixed → go to 64. Can't do it → go to 64.

How: see step 48.

56. What's left: Something on this circuit keeps tripping it.

57. Set the thermostat warmer (A). Fixed → done. Not fixed → go to 65. Can't do it → go to 65.

How: see step 34.

58. Set the thermostat warmer (A). Fixed → done. Not fixed → go to 66. Can't do it → go to 66.

How: see step 34.

59. Turn the thermostat off, then on again (A). Fixed → done. Not fixed → go to 67. Can't do it → go to 67.

  • Smell for gas first. At any smell, stop, and leave it alone.
  • Turn the thermostat, A, off, or all the way down.
  • Wait a few minutes.
  • Set it back to heat, a few degrees warmer than the room.
  • Listen for the burner to try. Do this once.
  • If it doesn't light, leave it, and choose that it didn't work.

60. Reset the breaker (L). Fixed → done. Not fixed → go to 68. Can't do it → go to 68.

Careful: Live electricity.

How: see step 33.

61. Turn its power switch on (B). Fixed → done. Not fixed → go to 69. Can't do it → go to 69.

How: see step 48.

62. Turn its power switch on (B). Fixed → done. Not fixed → go to 70. Can't do it → go to 70.

How: see step 48.

63. Turn the thermostat off, then on again (A). Fixed → done. Not fixed → go to 71. Can't do it → go to 71.

How: see step 59.

64. Reset the breaker (L). Fixed → done. Not fixed → go to 72. Can't do it → go to 72.

Careful: Live electricity.

How: see step 33.

65. Turn its power switch on (B). Fixed → done. Not fixed → go to 73. Can't do it → go to 73.

How: see step 48.

66. Turn its power switch on (B). Fixed → done. Not fixed → go to 74. Can't do it → go to 74.

How: see step 48.

67. Clear the drain tube (S). Fixed → done. Not fixed → go to 75. Can't do it → go to 75.

  • A high-efficiency furnace has white plastic pipes for its exhaust, and a small drain tube, S. No plastic pipes? Choose that it didn't work.
  • Follow the drain tube to where it ends. Clear, with no kink, crushed spot, ice or stopped drain? Choose that it didn't work.
  • Turn its power switch, B, off.
  • Straighten any kink in the drain tube, and free any crushed spot.
  • Lead the tube to an open drain indoors, where it can't be crushed or flattened.
  • If it runs outdoors in freezing weather, bring it indoors to a drain.
  • Turn the switch on. Listen for the burner to light.
  • Doesn't light? Choose that it didn't work.

68. Turn the thermostat off, then on again (A). Fixed → done. Not fixed → go to 76. Can't do it → go to 76.

How: see step 59.

69. Turn the thermostat off, then on again (A). Fixed → done. Not fixed → go to 77. Can't do it → go to 77.

How: see step 59.

70. Reset the breaker (L). Fixed → done. Not fixed → go to 78. Can't do it → go to 78.

Careful: Live electricity.

How: see step 33.

71. Light the pilot by the label (C). Fixed → done. Not fixed → go to 79. Can't do it → go to 79.

How: see step 11.

72. Turn the thermostat off, then on again (A). Fixed → done. Not fixed → go to 80. Can't do it → go to 80.

How: see step 59.

73. Turn the thermostat off, then on again (A). Fixed → done. Not fixed → go to 81. Can't do it → go to 81.

How: see step 59.

74. Reset the breaker (L). Fixed → done. Not fixed → go to 82. Can't do it → go to 82.

Careful: Live electricity.

How: see step 33.

75. What's left: Its ignition, or the control that watches its flame, has failed.

76. Clear the drain tube (S). Fixed → done. Not fixed → go to 83. Can't do it → go to 83.

How: see step 67.

77. Clear the drain tube (S). Fixed → done. Not fixed → go to 84. Can't do it → go to 84.

How: see step 67.

78. Turn the thermostat off, then on again (A). Fixed → done. Not fixed → go to 85. Can't do it → go to 85.

How: see step 59.

79. Clear the drain tube (S). Fixed → done. Not fixed → go to 86. Can't do it → go to 86.

How: see step 67.

80. Light the pilot by the label (C). Fixed → done. Not fixed → go to 87. Can't do it → go to 87.

How: see step 11.

81. Light the pilot by the label (C). Fixed → done. Not fixed → go to 88. Can't do it → go to 88.

How: see step 11.

82. Turn the thermostat off, then on again (A). Fixed → done. Not fixed → go to 89. Can't do it → go to 89.

How: see step 59.

83. What's left: Something on this circuit keeps tripping it · Its ignition, or the control that watches its flame, has failed.

84. Let the blower motor cool and restart it (E). Fixed → done. Not fixed → go to 90. Can't do it → go to 90.

Careful: Live electricity.

How: see step 25.

85. Clear the drain tube (S). Fixed → done. Not fixed → go to 91. Can't do it → go to 91.

How: see step 67.

86. What's left: Its ignition, or the control that watches its flame, has failed · The pilot won't stay lit.

87. Clear the drain tube (S). Fixed → done. Not fixed → go to 92. Can't do it → go to 92.

How: see step 67.

88. Clear the drain tube (S). Fixed → done. Not fixed → go to 93. Can't do it → go to 93.

How: see step 67.

89. Light the pilot by the label (C). Fixed → done. Not fixed → go to 94. Can't do it → go to 94.

How: see step 11.

90. What's left: The blower's belt is broken or off · The blower, its motor or its control has failed · The thermostat's wiring or the burner's own controls · Its ignition, or the control that watches its flame, has failed.

91. Let the blower motor cool and restart it (E). Fixed → done. Not fixed → go to 95. Can't do it → go to 95.

Careful: Live electricity.

How: see step 25.

92. What's left: Something on this circuit keeps tripping it · Its ignition, or the control that watches its flame, has failed · The pilot won't stay lit.

93. Let the blower motor cool and restart it (E). Fixed → done. Not fixed → go to 96. Can't do it → go to 96.

Careful: Live electricity.

How: see step 25.

94. Clear the drain tube (S). Fixed → done. Not fixed → go to 97. Can't do it → go to 97.

How: see step 67.

95. What's left: The blower's belt is broken or off · The blower, its motor or its control has failed · Something on this circuit keeps tripping it · The thermostat's wiring or the burner's own controls · Its ignition, or the control that watches its flame, has failed.

96. What's left: The blower's belt is broken or off · The blower, its motor or its control has failed · The thermostat's wiring or the burner's own controls · Its ignition, or the control that watches its flame, has failed · The pilot won't stay lit.

97. Let the blower motor cool and restart it (E). Fixed → done. Not fixed → go to 98. Can't do it → go to 98.

Careful: Live electricity.

How: see step 25.

98. What's left: The blower's belt is broken or off · The blower, its motor or its control has failed · Something on this circuit keeps tripping it · The thermostat's wiring or the burner's own controls · Its ignition, or the control that watches its flame, has failed · The pilot won't stay lit.

If it: No heat at all, and it burns oil

1. Do you smell gas in the house, or hear it hissing? Yes, I smell it or hear it → go to 2. No, I don't smell or hear gas → go to 3.

  • Notice any smell of gas as you walk in.
  • If you smell it, stop there and answer yes. Don't go on to the appliance.
  • If you smell nothing, listen near the appliance, without touching anything on it.
  • If the appliance is electric, answer for the house all the same.

2. Stop. Yes, I smell it or hear it

3. Is anyone feeling sick, or is a carbon monoxide alarm sounding? And look at the pipe that carries the furnace or boiler's smoke away. Someone feels sick, dizzy or weak, or an alarm is sounding → go to 4. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room → go to 5. None of that. Everyone's fine, and the pipe is whole → go to 6.

  • Ask everyone in the house if they feel sick, dizzy or weak.
  • Listen for a carbon monoxide alarm.
  • Notice any smoke or fumes coming into the room from the furnace or boiler.
  • Follow the metal pipe from the furnace or boiler to the chimney or the wall, by eye. Don't touch it. It can be hot.
  • Look for holes, spots rusted through, joints come apart, a gap, or a stretch that runs downhill.
  • Plastic vent pipes? Follow them to where they leave the house, and look that nothing blocks their ends outside.

4. Stop. Someone feels sick, dizzy or weak, or an alarm is sounding

5. Stop. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room

6. Has flood water reached it, up to its burner, or reached its ducts? Yes, or I can't tell → go to 7. No. Flood water never got near it → go to 8.

  • Think back over any flood in this room since it last ran.
  • Look low on it, where the burner sits, H, for a water line, mud or silt.
  • On a furnace, look at the ducts near the floor as well.

7. What's left: Flood water reached the burner or the ducts.

8. Does the gage on the oil tank show oil? It reads empty or nearly, or I can't read it → go to 9. It shows oil → go to 10.

  • Find the oil tank, D, and the gage on top of it.
  • Some gages read only roughly. Near empty counts as empty.

9. Fill the oil tank (D). Fixed → done. Not fixed → go to 11. Can't do it → go to 11.

  • Turn its power switch, B, off.
  • Fill the tank, D, with the heating oil it takes, the kind named on the tank or the burner.
  • Look at the gage. It should show oil now.
  • Look along the line and at the tank for any drip. At a drip, leave the switch off and choose that you can't do this one.
  • Turn the switch on. Give it a few minutes.
  • A burner that ran dry stops itself, and needs its reset, R, pressed. If anyone has pressed it since it stopped, don't. Choose that it didn't work.
  • Otherwise, let it sit a few minutes, so the control cools. Stand to one side of the burner, not in front of any door on it.
  • Press the reset once, and let go. Never hold it in.
  • If it doesn't light, or rumbles, puffs or smokes, turn the switch off. Don't press it again. Choose that it didn't work.

No spare? No oil to put in? Leave the switch off, so it doesn't run the pump dry.

10. Is the valve on the oil line open? A valve has been shut by hand → go to 12. A weight or lever has dropped, or a link has parted → go to 13. They're open, or I can't find a valve → go to 14.

  • Follow the oil line from the tank to the burner. Look for a valve at each end, K.
  • Look at whether each handle is open or shut.
  • Look for a weight or lever that has dropped, or a wire link that has parted, on a valve near the burner.

11. What's left: It ran dry, and the line has air in it, or the burner is soaked.

12. Open the valve on the oil line (K). Fixed → done. Not fixed → go to 15. Can't do it → go to 15.

  • If a weight or lever has dropped, or a link has parted, leave that valve shut, and choose that you can't do this one.
  • Ask who shut the valve, and why. If it was for a leak, a flood or a fire, leave it shut, and choose that you can't do this one.
  • Open the valve, K, all the way.
  • Look at the valve and along the line for oil dripping. At any drip, shut it again and choose that you can't do this one.
  • Turn its power switch, B, on. Give it a few minutes.
  • A burner that ran dry stops itself, and needs its reset, R, pressed. If anyone has pressed it since it stopped, don't. Choose that it didn't work.
  • Otherwise, let it sit a few minutes, so the control cools. Stand to one side of the burner, not in front of any door on it.
  • Press the reset once, and let go. Never hold it in.
  • If it doesn't light, or rumbles, puffs or smokes, turn the switch off. Don't press it again. Choose that it didn't work.

13. What's left: The fire valve on the oil line has closed.

14. With the thermostat set warmer, does the burner light, and then does warm air blow? The burner doesn't light → go to 16. It lights, but no air blows, or it soon shuts off → go to 17. It lights, and warm air blows → go to 18. Can't check? → go to 19.

  • Smell for gas first. At any smell, stop, leave the house, and go back to the first question.
  • Set the thermostat, A, a few degrees warmer than the room.
  • Watch the burner's window, H, or listen for it to light.
  • Once it's lit, wait a few minutes, then hold a hand at a register in a room.

15. What's left: It ran dry, and the line has air in it, or the burner is soaked.

16. Do the lights work in the rest of the house? No, the power is out → go to 20. Yes, the lights work → go to 21.

  • Try a light in another room.
  • Try the light nearest it, if there is one.

17. Change or wash the air filter (F). Fixed → done. Not fixed → go to 22. Can't do it → go to 22.

Careful: Live electricity.

  • Turn its power switch, B, off, and wait for the blower to stop.
  • Filter behind the blower's door, E? Turn off its breaker, L, too, before you open the door, and leave the breaker panel's own cover on. Can't tell which breaker? Choose that you can't do this one.
  • Slide the filter out of its slot, F. Note which way its arrow points.
  • Hold it up to a light. If light comes through it easily, it's clean. Slide it back, close any door, turn the power back on, and choose that it didn't work.
  • Fit a new filter of the same size, with its arrow pointing the way the air flows, toward the blower.
  • A washable filter, wash it, let it dry, and spray it with filter adhesive as its can says before it goes back.
  • Close any door. Turn the breaker back on if you turned it off, then the switch.

No spare? No clean filter? The Navy's stopgap is to run without it until you have one. Put one back as soon as you can, because dust gets into the blower.

18. What's left: The thermostat's wiring or the burner's own controls.

19. Do the lights work in the rest of the house? No, the power is out → go to 23. Yes, the lights work → go to 24.

How: see step 16.

20. What's left: The house has no power.

21. Is its breaker on, and its fuse good? It's off, in the middle, or the fuse is blown → go to 25. It's on, and the fuse is good → go to 26. Can't check? → go to 27.

Careful: Live electricity.

  • If the floor by the panel is wet, don't go to it. Choose that you can't check this.
  • Stand on a dry spot, with dry hands.
  • Open the panel door, L. Leave the cover behind it on.
  • Find the handle or fuse for this machine, if it's labeled.
  • Look for a handle at off, or just short of on, or a blown fuse.

22. Let the blower motor cool and restart it (E). Fixed → done. Not fixed → go to 28. Can't do it → go to 28.

Careful: Live electricity.

  • Turn its power switch, B, off.
  • Can't tell which breaker at the panel feeds the furnace? Choose that you can't do this one.
  • Turn off its breaker, L, too, before you open anything. Leave the breaker panel's own cover on.
  • Open the blower's door, E, and let the motor cool.
  • Turn the blower wheel by hand. It should turn freely. If it binds or grinds, close the door and choose that you can't do this one.
  • If the motor has a reset button, press it once.
  • Close the door. Turn the breaker on, then the switch.
  • Listen for the blower when the burner is lit. If it stops again, turn the switch off and leave it off.

23. What's left: The house has no power.

24. Is its breaker on, and its fuse good? It's off, in the middle, or the fuse is blown → go to 29. It's on, and the fuse is good → go to 30. Can't check? → go to 31.

Careful: Live electricity.

How: see step 21.

25. Reset the breaker (L). Fixed → done. Not fixed → go to 32. Can't do it → go to 32.

Careful: Live electricity.

  • If the floor by the panel is wet, don't go to it. Say you can't.
  • Stand on a dry spot, with dry hands.
  • If the handle is at off, push it to on.
  • If it sits near the middle, push it firmly to off, then to on.
  • For a blown fuse, turn off what's on that circuit and screw in a new fuse of the same size. Put nothing else in the holder.
  • If it trips again, stand clear and leave it off.

26. Since the burner stopped, has anyone pressed its reset button? Yes, or I'm not sure → go to 33. No → go to 34.

  • Find the reset button on the burner, R. It's on the box of controls on the burner, often red.
  • Ask everyone in the house. Once counts.

27. Since the burner stopped, has anyone pressed its reset button? Yes, or I'm not sure → go to 35. No → go to 36.

How: see step 26.

28. What's left: The blower's belt is broken or off · The blower, its motor or its control has failed.

29. Reset the breaker (L). Fixed → done. Not fixed → go to 37. Can't do it → go to 37.

Careful: Live electricity.

How: see step 25.

30. Since the burner stopped, has anyone pressed its reset button? Yes, or I'm not sure → go to 38. No → go to 39.

How: see step 26.

31. Since the burner stopped, has anyone pressed its reset button? Yes, or I'm not sure → go to 40. No → go to 41.

How: see step 26.

32. What's left: Something on this circuit keeps tripping it.

33. What's left: The reset has been pressed, and the burner may be soaked with oil.

34. Set the thermostat warmer (A). Fixed → done. Not fixed → go to 42. Can't do it → go to 42.

  • Look at the thermostat, A. Already set to heat, and warmer than the room? Choose that it didn't work.
  • Set it to heat, the way its own instructions show.
  • Set it a few degrees warmer than the room.
  • Give it a few minutes. Listen for the burner to start.
  • Doesn't start? Choose that it didn't work.

35. What's left: The reset has been pressed, and the burner may be soaked with oil.

36. Set the thermostat warmer (A). Fixed → done. Not fixed → go to 43. Can't do it → go to 43.

How: see step 34.

37. What's left: Something on this circuit keeps tripping it.

38. What's left: The reset has been pressed, and the burner may be soaked with oil.

39. Change or wash the air filter (F). Fixed → done. Not fixed → go to 44. Can't do it → go to 44.

Careful: Live electricity.

How: see step 17.

40. What's left: The reset has been pressed, and the burner may be soaked with oil.

41. Change or wash the air filter (F). Fixed → done. Not fixed → go to 45. Can't do it → go to 45.

Careful: Live electricity.

How: see step 17.

42. Turn its power switch on (B). Fixed → done. Not fixed → go to 46. Can't do it → go to 46.

  • Find its own switch, B. It often looks like a light switch, on it, on the wall beside it, or at the top of the stairs.
  • Already on, or no switch to find? Choose that it didn't work.
  • Ask who turned it off, and why. If it was for a gas smell, smoke, water or a fault, leave it off and choose that you can't do this one.
  • Turn the switch on.
  • Give it a few minutes. Listen for the burner to start.
  • Doesn't start? Choose that it didn't work.

43. Turn its power switch on (B). Fixed → done. Not fixed → go to 47. Can't do it → go to 47.

How: see step 42.

44. Set the thermostat warmer (A). Fixed → done. Not fixed → go to 48. Can't do it → go to 48.

How: see step 34.

45. Set the thermostat warmer (A). Fixed → done. Not fixed → go to 49. Can't do it → go to 49.

How: see step 34.

46. Press the burner's reset button once (R). Fixed → done. Not fixed → go to 50. Can't do it → go to 50.

  • Has anyone pressed it already since the burner stopped? Then don't. Choose that you can't do this one.
  • Let it sit a few minutes after it stopped, so the control cools.
  • Stand to one side of the burner, not in front of any door on it.
  • Press the reset button, R, once, and let go. Never hold it in.
  • If it lights and runs smoothly, let it run.
  • If it rumbles, puffs or smokes, turn its switch, B, off and choose that it didn't work.
  • If it doesn't light, don't press it again. Turn the switch off and choose that it didn't work.

47. Press the burner's reset button once (R). Fixed → done. Not fixed → go to 51. Can't do it → go to 51.

How: see step 46.

48. Turn its power switch on (B). Fixed → done. Not fixed → go to 52. Can't do it → go to 52.

How: see step 42.

49. Turn its power switch on (B). Fixed → done. Not fixed → go to 53. Can't do it → go to 53.

How: see step 42.

50. What's left: The oil line or the burner itself · The burner didn't light after the reset, and may be soaked with oil.

51. Reset the breaker (L). Fixed → done. Not fixed → go to 54. Can't do it → go to 54.

Careful: Live electricity.

How: see step 25.

52. Press the burner's reset button once (R). Fixed → done. Not fixed → go to 55. Can't do it → go to 55.

How: see step 46.

53. Press the burner's reset button once (R). Fixed → done. Not fixed → go to 56. Can't do it → go to 56.

How: see step 46.

54. What's left: Something on this circuit keeps tripping it · The oil line or the burner itself · The burner didn't light after the reset, and may be soaked with oil.

55. Let the blower motor cool and restart it (E). Fixed → done. Not fixed → go to 57. Can't do it → go to 57.

Careful: Live electricity.

How: see step 22.

56. Reset the breaker (L). Fixed → done. Not fixed → go to 58. Can't do it → go to 58.

Careful: Live electricity.

How: see step 25.

57. What's left: The blower's belt is broken or off · The blower, its motor or its control has failed · The thermostat's wiring or the burner's own controls · The oil line or the burner itself · The burner didn't light after the reset, and may be soaked with oil.

58. Let the blower motor cool and restart it (E). Fixed → done. Not fixed → go to 59. Can't do it → go to 59.

Careful: Live electricity.

How: see step 22.

59. What's left: The blower's belt is broken or off · The blower, its motor or its control has failed · Something on this circuit keeps tripping it · The thermostat's wiring or the burner's own controls · The oil line or the burner itself · The burner didn't light after the reset, and may be soaked with oil.

If it: Heat comes, but it's weak, or some rooms stay cold

1. Do you smell gas in the house, or hear it hissing? Yes, I smell it or hear it → go to 2. No, I don't smell or hear gas → go to 3.

  • Notice any smell of gas as you walk in.
  • If you smell it, stop there and answer yes. Don't go on to the appliance.
  • If you smell nothing, listen near the appliance, without touching anything on it.
  • If the appliance is electric, answer for the house all the same.

2. Stop. Yes, I smell it or hear it

3. Is anyone feeling sick, or is a carbon monoxide alarm sounding? And look at the pipe that carries the furnace or boiler's smoke away. Someone feels sick, dizzy or weak, or an alarm is sounding → go to 4. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room → go to 5. None of that. Everyone's fine, and the pipe is whole → go to 6.

  • Ask everyone in the house if they feel sick, dizzy or weak.
  • Listen for a carbon monoxide alarm.
  • Notice any smoke or fumes coming into the room from the furnace or boiler.
  • Follow the metal pipe from the furnace or boiler to the chimney or the wall, by eye. Don't touch it. It can be hot.
  • Look for holes, spots rusted through, joints come apart, a gap, or a stretch that runs downhill.
  • Plastic vent pipes? Follow them to where they leave the house, and look that nothing blocks their ends outside.

4. Stop. Someone feels sick, dizzy or weak, or an alarm is sounding

5. Stop. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room

6. Has flood water reached it, up to its burner, or reached its ducts? Yes, or I can't tell → go to 7. No. Flood water never got near it → go to 8.

  • Think back over any flood in this room since it last ran.
  • Look low on it, where the burner sits, H, for a water line, mud or silt.
  • On a furnace, look at the ducts near the floor as well.

7. What's left: Flood water reached the burner or the ducts.

8. Change or wash the air filter (F). Fixed → done. Not fixed → go to 9. Can't do it → go to 9.

Careful: Live electricity.

  • Turn its power switch, B, off, and wait for the blower to stop.
  • Filter behind the blower's door, E? Turn off its breaker, L, too, before you open the door, and leave the breaker panel's own cover on. Can't tell which breaker? Choose that you can't do this one.
  • Slide the filter out of its slot, F. Note which way its arrow points.
  • Hold it up to a light. If light comes through it easily, it's clean. Slide it back, close any door, turn the power back on, and choose that it didn't work.
  • Fit a new filter of the same size, with its arrow pointing the way the air flows, toward the blower.
  • A washable filter, wash it, let it dry, and spray it with filter adhesive as its can says before it goes back.
  • Close any door. Turn the breaker back on if you turned it off, then the switch.

No spare? No clean filter? The Navy's stopgap is to run without it until you have one. Put one back as soon as you can, because dust gets into the blower.

9. Stop the cold air coming in. Fixed → done. Not fixed → go to 10. Can't do it → go to 10.

  • Walk the cold rooms. Feel for cold air at windows, doors and cracks, low down by the floor.
  • None? Choose that it didn't work.
  • Shut any window or door that is open.
  • Tighten loose windows with their latches.
  • Seal the cracks round windows and doors with tape, rope caulk or a rolled towel.
  • Give the house an hour to warm.
  • Still cold after that? Choose that it didn't work.

10. Open the dampers (Q). Fixed → done. Not fixed → go to 11. Can't do it → go to 11.

  • Find any small handles on the ducts, Q, near the furnace and along the ducts to the cold rooms. Each turns a flap inside.
  • None, or none has been moved? Choose that it didn't work.
  • Turn each one that is shut or part shut to open. On most, open is when the handle runs along the duct.
  • Not sure which way is open? Turn one, then feel the air at a register in that room.
  • A handle that is missing, leave. Don't cut into a duct.

11. Take up the slack in the blower's belt (E). Fixed → done. Not fixed → go to 12. Can't do it → go to 12.

Careful: Live electricity.

  • Turn its power switch, B, off, and wait for the blower to stop.
  • Can't tell which breaker at the panel feeds the furnace? Choose that you can't do this one.
  • Turn off its breaker, L, too, before you open anything. Leave the breaker panel's own cover on.
  • Open the blower's door, E. Look at the belt between the motor and the blower, and press it with a finger.
  • No belt, because the motor turns the blower straight? Or the belt is firm and not shiny? Close the door, turn the breaker on, then the switch, and choose that it didn't work.
  • Broken, or off its wheels? Close the door and choose that you can't do this one.
  • Loosen the bolts that hold the motor to its base.
  • Slide the motor away from the blower until the belt stops slipping, with the give your furnace's manual names. Not tight. A tight belt overloads the motor.
  • Tighten the bolts.
  • Turn the blower wheel by hand. It should turn freely.
  • Close the door. Turn the breaker on, then the switch.

12. What's left: The ducts or the blower's speed.

If it: Rooms get hot, then cold

1. Do you smell gas in the house, or hear it hissing? Yes, I smell it or hear it → go to 2. No, I don't smell or hear gas → go to 3.

  • Notice any smell of gas as you walk in.
  • If you smell it, stop there and answer yes. Don't go on to the appliance.
  • If you smell nothing, listen near the appliance, without touching anything on it.
  • If the appliance is electric, answer for the house all the same.

2. Stop. Yes, I smell it or hear it

3. Is anyone feeling sick, or is a carbon monoxide alarm sounding? And look at the pipe that carries the furnace or boiler's smoke away. Someone feels sick, dizzy or weak, or an alarm is sounding → go to 4. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room → go to 5. None of that. Everyone's fine, and the pipe is whole → go to 6.

  • Ask everyone in the house if they feel sick, dizzy or weak.
  • Listen for a carbon monoxide alarm.
  • Notice any smoke or fumes coming into the room from the furnace or boiler.
  • Follow the metal pipe from the furnace or boiler to the chimney or the wall, by eye. Don't touch it. It can be hot.
  • Look for holes, spots rusted through, joints come apart, a gap, or a stretch that runs downhill.
  • Plastic vent pipes? Follow them to where they leave the house, and look that nothing blocks their ends outside.

4. Stop. Someone feels sick, dizzy or weak, or an alarm is sounding

5. Stop. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room

6. Has flood water reached it, up to its burner, or reached its ducts? Yes, or I can't tell → go to 7. No. Flood water never got near it → go to 8.

  • Think back over any flood in this room since it last ran.
  • Look low on it, where the burner sits, H, for a water line, mud or silt.
  • On a furnace, look at the ducts near the floor as well.

7. What's left: Flood water reached the burner or the ducts.

8. Run the blower all the time (A). Fixed → done. Not fixed → go to 9. Can't do it → go to 9.

  • Find the fan switch on the thermostat, A. No fan switch? Choose that you can't do this one.
  • Already set to On? Choose that it didn't work.
  • Set it to On, the way its own instructions show.
  • The blower now runs all the time, and the burner still comes and goes.
  • Give the house an hour or two. If the swings stop, leave it on.
  • Still swinging after that? Choose that it didn't work.

9. What's left: The thermostat's wiring or the burner's own controls.

If it: It runs, then shuts off, or starts and stops often

1. Do you smell gas in the house, or hear it hissing? Yes, I smell it or hear it → go to 2. No, I don't smell or hear gas → go to 3.

  • Notice any smell of gas as you walk in.
  • If you smell it, stop there and answer yes. Don't go on to the appliance.
  • If you smell nothing, listen near the appliance, without touching anything on it.
  • If the appliance is electric, answer for the house all the same.

2. Stop. Yes, I smell it or hear it

3. Is anyone feeling sick, or is a carbon monoxide alarm sounding? And look at the pipe that carries the furnace or boiler's smoke away. Someone feels sick, dizzy or weak, or an alarm is sounding → go to 4. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room → go to 5. None of that. Everyone's fine, and the pipe is whole → go to 6.

  • Ask everyone in the house if they feel sick, dizzy or weak.
  • Listen for a carbon monoxide alarm.
  • Notice any smoke or fumes coming into the room from the furnace or boiler.
  • Follow the metal pipe from the furnace or boiler to the chimney or the wall, by eye. Don't touch it. It can be hot.
  • Look for holes, spots rusted through, joints come apart, a gap, or a stretch that runs downhill.
  • Plastic vent pipes? Follow them to where they leave the house, and look that nothing blocks their ends outside.

4. Stop. Someone feels sick, dizzy or weak, or an alarm is sounding

5. Stop. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room

6. Has flood water reached it, up to its burner, or reached its ducts? Yes, or I can't tell → go to 7. No. Flood water never got near it → go to 8.

  • Think back over any flood in this room since it last ran.
  • Look low on it, where the burner sits, H, for a water line, mud or silt.
  • On a furnace, look at the ducts near the floor as well.

7. What's left: Flood water reached the burner or the ducts.

8. With the thermostat set warmer, does the burner light, and then does warm air blow? The burner doesn't light → go to 9. It lights, but no air blows, or it soon shuts off → go to 10. It lights, and warm air blows → go to 11. Can't check? → go to 12.

  • Smell for gas first. At any smell, stop, leave the house, and go back to the first question.
  • Set the thermostat, A, a few degrees warmer than the room.
  • Watch the burner's window, H, or listen for it to light.
  • Once it's lit, wait a few minutes, then hold a hand at a register in a room.

9. Clear the drain tube (S). Fixed → done. Not fixed → go to 13. Can't do it → go to 13.

  • A high-efficiency furnace has white plastic pipes for its exhaust, and a small drain tube, S. No plastic pipes? Choose that it didn't work.
  • Follow the drain tube to where it ends. Clear, with no kink, crushed spot, ice or stopped drain? Choose that it didn't work.
  • Turn its power switch, B, off.
  • Straighten any kink in the drain tube, and free any crushed spot.
  • Lead the tube to an open drain indoors, where it can't be crushed or flattened.
  • If it runs outdoors in freezing weather, bring it indoors to a drain.
  • Turn the switch on. Listen for the burner to light.
  • Doesn't light? Choose that it didn't work.

10. Change or wash the air filter (F). Fixed → done. Not fixed → go to 14. Can't do it → go to 14.

Careful: Live electricity.

  • Turn its power switch, B, off, and wait for the blower to stop.
  • Filter behind the blower's door, E? Turn off its breaker, L, too, before you open the door, and leave the breaker panel's own cover on. Can't tell which breaker? Choose that you can't do this one.
  • Slide the filter out of its slot, F. Note which way its arrow points.
  • Hold it up to a light. If light comes through it easily, it's clean. Slide it back, close any door, turn the power back on, and choose that it didn't work.
  • Fit a new filter of the same size, with its arrow pointing the way the air flows, toward the blower.
  • A washable filter, wash it, let it dry, and spray it with filter adhesive as its can says before it goes back.
  • Close any door. Turn the breaker back on if you turned it off, then the switch.

No spare? No clean filter? The Navy's stopgap is to run without it until you have one. Put one back as soon as you can, because dust gets into the blower.

11. Take up the slack in the blower's belt (E). Fixed → done. Not fixed → go to 15. Can't do it → go to 15.

Careful: Live electricity.

  • Turn its power switch, B, off, and wait for the blower to stop.
  • Can't tell which breaker at the panel feeds the furnace? Choose that you can't do this one.
  • Turn off its breaker, L, too, before you open anything. Leave the breaker panel's own cover on.
  • Open the blower's door, E. Look at the belt between the motor and the blower, and press it with a finger.
  • No belt, because the motor turns the blower straight? Or the belt is firm and not shiny? Close the door, turn the breaker on, then the switch, and choose that it didn't work.
  • Broken, or off its wheels? Close the door and choose that you can't do this one.
  • Loosen the bolts that hold the motor to its base.
  • Slide the motor away from the blower until the belt stops slipping, with the give your furnace's manual names. Not tight. A tight belt overloads the motor.
  • Tighten the bolts.
  • Turn the blower wheel by hand. It should turn freely.
  • Close the door. Turn the breaker on, then the switch.

12. Change or wash the air filter (F). Fixed → done. Not fixed → go to 16. Can't do it → go to 16.

Careful: Live electricity.

How: see step 10.

13. What's left: Its ignition, or the control that watches its flame, has failed.

14. Let the blower motor cool and restart it (E). Fixed → done. Not fixed → go to 17. Can't do it → go to 17.

Careful: Live electricity.

  • Turn its power switch, B, off.
  • Can't tell which breaker at the panel feeds the furnace? Choose that you can't do this one.
  • Turn off its breaker, L, too, before you open anything. Leave the breaker panel's own cover on.
  • Open the blower's door, E, and let the motor cool.
  • Turn the blower wheel by hand. It should turn freely. If it binds or grinds, close the door and choose that you can't do this one.
  • If the motor has a reset button, press it once.
  • Close the door. Turn the breaker on, then the switch.
  • Listen for the blower when the burner is lit. If it stops again, turn the switch off and leave it off.

15. What's left: The thermostat's wiring or the burner's own controls.

16. Clear the drain tube (S). Fixed → done. Not fixed → go to 18. Can't do it → go to 18.

How: see step 9.

17. What's left: The blower's belt is broken or off · The blower, its motor or its control has failed · It keeps shutting off on its high limit.

18. Let the blower motor cool and restart it (E). Fixed → done. Not fixed → go to 19. Can't do it → go to 19.

Careful: Live electricity.

How: see step 14.

19. Take up the slack in the blower's belt (E). Fixed → done. Not fixed → go to 20. Can't do it → go to 20.

Careful: Live electricity.

How: see step 11.

20. What's left: The blower's belt is broken or off · The blower, its motor or its control has failed · The thermostat's wiring or the burner's own controls · Its ignition, or the control that watches its flame, has failed · It keeps shutting off on its high limit.

If it: Smoke, soot or a burning or oily smell

1. Do you smell gas in the house, or hear it hissing? Yes, I smell it or hear it → go to 2. No, I don't smell or hear gas → go to 3.

  • Notice any smell of gas as you walk in.
  • If you smell it, stop there and answer yes. Don't go on to the appliance.
  • If you smell nothing, listen near the appliance, without touching anything on it.
  • If the appliance is electric, answer for the house all the same.

2. Stop. Yes, I smell it or hear it

3. Is anyone feeling sick, or is a carbon monoxide alarm sounding? And look at the pipe that carries the furnace or boiler's smoke away. Someone feels sick, dizzy or weak, or an alarm is sounding → go to 4. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room → go to 5. None of that. Everyone's fine, and the pipe is whole → go to 6.

  • Ask everyone in the house if they feel sick, dizzy or weak.
  • Listen for a carbon monoxide alarm.
  • Notice any smoke or fumes coming into the room from the furnace or boiler.
  • Follow the metal pipe from the furnace or boiler to the chimney or the wall, by eye. Don't touch it. It can be hot.
  • Look for holes, spots rusted through, joints come apart, a gap, or a stretch that runs downhill.
  • Plastic vent pipes? Follow them to where they leave the house, and look that nothing blocks their ends outside.

4. Stop. Someone feels sick, dizzy or weak, or an alarm is sounding

5. Stop. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room

6. What's left: It isn't burning cleanly.

If it: The power is out

1. Do you smell gas in the house, or hear it hissing? Yes, I smell it or hear it → go to 2. No, I don't smell or hear gas → go to 3.

  • Notice any smell of gas as you walk in.
  • If you smell it, stop there and answer yes. Don't go on to the appliance.
  • If you smell nothing, listen near the appliance, without touching anything on it.
  • If the appliance is electric, answer for the house all the same.

2. Stop. Yes, I smell it or hear it

3. Is anyone feeling sick, or is a carbon monoxide alarm sounding? And look at the pipe that carries the furnace or boiler's smoke away. Someone feels sick, dizzy or weak, or an alarm is sounding → go to 4. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room → go to 5. None of that. Everyone's fine, and the pipe is whole → go to 6.

  • Ask everyone in the house if they feel sick, dizzy or weak.
  • Listen for a carbon monoxide alarm.
  • Notice any smoke or fumes coming into the room from the furnace or boiler.
  • Follow the metal pipe from the furnace or boiler to the chimney or the wall, by eye. Don't touch it. It can be hot.
  • Look for holes, spots rusted through, joints come apart, a gap, or a stretch that runs downhill.
  • Plastic vent pipes? Follow them to where they leave the house, and look that nothing blocks their ends outside.

4. Stop. Someone feels sick, dizzy or weak, or an alarm is sounding

5. Stop. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room

6. What's left: The house has no power.

If it: Water around the furnace

1. Do you smell gas in the house, or hear it hissing? Yes, I smell it or hear it → go to 2. No, I don't smell or hear gas → go to 3.

  • Notice any smell of gas as you walk in.
  • If you smell it, stop there and answer yes. Don't go on to the appliance.
  • If you smell nothing, listen near the appliance, without touching anything on it.
  • If the appliance is electric, answer for the house all the same.

2. Stop. Yes, I smell it or hear it

3. Is anyone feeling sick, or is a carbon monoxide alarm sounding? And look at the pipe that carries the furnace or boiler's smoke away. Someone feels sick, dizzy or weak, or an alarm is sounding → go to 4. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room → go to 5. None of that. Everyone's fine, and the pipe is whole → go to 6.

  • Ask everyone in the house if they feel sick, dizzy or weak.
  • Listen for a carbon monoxide alarm.
  • Notice any smoke or fumes coming into the room from the furnace or boiler.
  • Follow the metal pipe from the furnace or boiler to the chimney or the wall, by eye. Don't touch it. It can be hot.
  • Look for holes, spots rusted through, joints come apart, a gap, or a stretch that runs downhill.
  • Plastic vent pipes? Follow them to where they leave the house, and look that nothing blocks their ends outside.

4. Stop. Someone feels sick, dizzy or weak, or an alarm is sounding

5. Stop. The pipe is blocked, holed, come apart or missing, or smoke is coming into the room

6. Has flood water reached it, up to its burner, or reached its ducts? Yes, or I can't tell → go to 7. No. Flood water never got near it → go to 8.

  • Think back over any flood in this room since it last ran.
  • Look low on it, where the burner sits, H, for a water line, mud or silt.
  • On a furnace, look at the ducts near the floor as well.

7. What's left: Flood water reached the burner or the ducts.

8. Free the humidifier's float (T). Fixed → done. Not fixed → go to 9. Can't do it → go to 9.

  • Some furnaces have a pan of water on the ducts, T, with a float that lets water in. No pan, or it isn't running over? Choose that it didn't work.
  • Turn its power switch, B, off before you reach in.
  • Lift the float ball in the pan up and down a few times, to let the water wash its seat.
  • Watch the water level. It should stop below the pan's edge.
  • If it still overflows, turn off the small valve on the water line to the humidifier.
  • Wipe up water that ran onto the furnace. Turn the switch back on once it's dry.

9. Clear the drain tube (S). Fixed → done. Not fixed → go to 10. Can't do it → go to 10.

  • A high-efficiency furnace has white plastic pipes for its exhaust, and a small drain tube, S. No plastic pipes? Choose that it didn't work.
  • Follow the drain tube to where it ends. Clear, with no kink, crushed spot, ice or stopped drain? Choose that it didn't work.
  • Turn its power switch, B, off.
  • Straighten any kink in the drain tube, and free any crushed spot.
  • Lead the tube to an open drain indoors, where it can't be crushed or flattened.
  • If it runs outdoors in freezing weather, bring it indoors to a drain.
  • Turn the switch on. Listen for the burner to light.
  • Doesn't light? Choose that it didn't work.

10. What's left: Water from somewhere else.

How to get by

Sources

  • TM 5-642, Operation and Maintenance: Small Heating Systems (oil and gas burners, steam and hot-water boilers, warm-air furnaces), Chapter 3, oil and gas burners; chapter 6, warm-air furnaces
  • NAVEDTRA 12532, Utilitiesman 3 (rate training manual), chapter 9: furnace filters, furnace troubleshooting and gas burner maintenance, the pilot safety valve, Chapter 9, furnaces, troubleshooting, pilot safety valve
  • NAVEDTRA 10662, Utilitiesman 2 (rate training manual), chapters 9 and 10: oil-burner controls and troubleshooting, Table 9-1, hot-water relief valve, air vents, circulating pumps, troubleshooting, Chapter 9, oil-burner controls and troubleshooting
  • NAVEDTRA 10662, Utilitiesman 2 (rate training manual), chapter 9: pilot light, thermocouple, relay, limit control, Chapter 9, pilot light and thermocouple
  • Oil Burners for Home Heating (Circular No. 406), Emergency or Safety Controls; Care of Burners
  • Home Heating: Systems, Fuels, Controls (Farmers' Bulletin No. 2235), Gas, pp. 20 and 21
  • Repairing Your Flooded Home (FEMA P-234 / ARC 4477): flooded ducts, the furnace blower, and flooded gas and oil appliances, Steps 2, 4 and 5
  • Power Outages and Indoor Air Quality (IAQ), Heating: Combustion Appliances

Open it in Minuteman. In the app it works with no signal.