The parts

  • A: the panel door
  • B: the main breaker, usually at the top
  • C: the rows of breaker handles
  • E: a fuse, in a fuse box
  • F: a GFCI outlet, with test and reset buttons
  • V: the watts label on an appliance

If it: One room or circuit is dead

1. Is there water, smoke or sparks near it, a smell of hot insulation, or has anyone felt a shock? There's water on the floor, or it has been wet or flooded → go to 2. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock → go to 3. No. It's dry, and none of that → go to 4.

  • Look at the floor where you would stand. Water that belongs there, like a sump pit, doesn't count. Water over the floor does.
  • Look and sniff around it, without touching it.
  • Ask if anyone felt a shock from it, even a mild tingle.

2. Stop. There's water on the floor, or it has been wet or flooded

3. Stop. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock

4. Is any breaker off or in the middle, or is a fuse blown? A breaker is off or in the middle → go to 5. A fuse is blown → go to 6. They all look on and whole → go to 7.

Careful: Live electricity.

  • Stand on a dry spot, with dry hands.
  • Open the panel door, A. Leave the cover behind it on.
  • Look along the handles, C, for one that is off, or sits just short of on.
  • If you have a fuse box, look at each fuse, E.

5. Reset the breaker (C). Fixed → done. Not fixed → go to 8. Can't do it → go to 8.

Careful: Live electricity.

  • Stand on a dry spot, with dry hands.
  • Turn off or unplug what's on that circuit.
  • If the handle is at off, push it to on.
  • If it sits near the middle, push it firmly to off, then to on.
  • Stand clear of the panel if it trips again, and leave it off.
  • Turn things back on one at a time.

No spare? It won't stay on? Leave it off, and move what matters to another circuit with a sound cord.

6. Replace the blown fuse (E). Fixed → done. Not fixed → go to 9. Can't do it → go to 9.

Careful: Live electricity.

  • Stand on a dry spot, with dry hands.
  • Turn off or unplug what's on that circuit.
  • If the box has a handle on its side, pull it to off.
  • Unscrew the blown fuse, E.
  • Screw in a new fuse of the size named in the entry above.
  • Put nothing else in the holder, ever.
  • Push the handle back to on.

No spare? No spare fuse of the right size? Take one from a circuit you can do without.

7. Reset the GFCI (F). Fixed → done. Not fixed → go to 10. Can't do it → go to 10.

  • Unplug what's on that outlet.
  • Find the outlet with test and reset buttons, F. It may be in another room on the same circuit.
  • Look in bathrooms and outdoors first, then along that circuit.
  • Press its reset button.
  • Plug a lamp into the dead outlet and turn it on.

No spare? It won't reset? Leave it, and use an outlet on another circuit.

8. What's left: That didn't fix it, and nothing else on this list fits what you found. If anything has changed, start over.

9. What's left: That didn't fix it, and nothing else on this list fits what you found. If anything has changed, start over.

10. What's left: The breaker itself has failed · A connection in the wall has come loose.

If it: A breaker keeps tripping, or a fuse keeps blowing

1. Is there water, smoke or sparks near it, a smell of hot insulation, or has anyone felt a shock? There's water on the floor, or it has been wet or flooded → go to 2. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock → go to 3. No. It's dry, and none of that → go to 4.

  • Look at the floor where you would stand. Water that belongs there, like a sump pit, doesn't count. Water over the floor does.
  • Look and sniff around it, without touching it.
  • Ask if anyone felt a shock from it, even a mild tingle.

2. Stop. There's water on the floor, or it has been wet or flooded

3. Stop. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock

4. What happens each time it trips? It goes when one appliance is on → go to 5. It goes when several things are on → go to 6. It goes when one wall switch or outlet is used, or with nothing on → go to 7.

  • Think about what was on each time it tripped.
  • Can't tell? Keep track of it the next few times before you reset it again.

5. Take that appliance out of use (C). Fixed → done. Not fixed → go to 8. Can't do it → go to 8.

Careful: Live electricity.

  • Unplug it.
  • Reset the breaker, C, or replace the fuse, E.
  • Leave the appliance unplugged. It can start a fire or give a shock.

No spare? Use something else to do its job, or go without it.

6. Move something to another circuit (V). Fixed → done. Not fixed → go to 9. Can't do it → go to 9.

Careful: Live electricity.

  • Find the watts on the label, V, of each thing on that circuit.
  • Add them up, against what the entry above says a branch can carry.
  • Move something to an outlet on a circuit with less on it.
  • Reset the breaker, C, or replace the fuse, E.

No spare? Nowhere to move it? Run one thing at a time on that circuit.

7. What's left: A switch, an outlet or a wire in the wall has a fault.

8. What's left: That didn't fix it, and nothing else on this list fits what you found. If anything has changed, start over.

9. What's left: That didn't fix it, and nothing else on this list fits what you found. If anything has changed, start over.

If it: A GFCI outlet is dead or keeps cutting off

1. Is there water, smoke or sparks near it, a smell of hot insulation, or has anyone felt a shock? There's water on the floor, or it has been wet or flooded → go to 2. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock → go to 3. No. It's dry, and none of that → go to 4.

  • Look at the floor where you would stand. Water that belongs there, like a sump pit, doesn't count. Water over the floor does.
  • Look and sniff around it, without touching it.
  • Ask if anyone felt a shock from it, even a mild tingle.

2. Stop. There's water on the floor, or it has been wet or flooded

3. Stop. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock

4. Reset the GFCI (F). Fixed → done. Not fixed → go to 5. Can't do it → go to 5.

  • Unplug what's on that outlet.
  • Find the outlet with test and reset buttons, F. It may be in another room on the same circuit.
  • Look in bathrooms and outdoors first, then along that circuit.
  • Press its reset button.
  • Plug a lamp into the dead outlet and turn it on.

No spare? It won't reset? Leave it, and use an outlet on another circuit.

5. Does it cut off when one thing is plugged in? Yes, when one thing goes in → go to 6. No, it cuts off or won't reset with nothing plugged in → go to 7.

  • Unplug everything on that outlet and the ones near it.
  • Reset the GFCI, F.
  • Plug things back in one at a time.

6. Keep that thing unplugged (F). Fixed → done. Not fixed → go to 8. Can't do it → go to 8.

  • Unplug it.
  • Reset the GFCI, F.
  • Leave it unplugged. It can start a fire or give a shock.

No spare? Use something else to do its job, or go without it.

7. Does the GFCI pass its test? The lamp did not go out, or did not come back → go to 9. It went out and came back → go to 10.

  • Plug a lamp into the outlet, F, and turn it on.
  • Press the test button. The lamp should go out.
  • Press the reset button. The lamp should come back on.

8. What's left: That didn't fix it, and nothing else on this list fits what you found. If anything has changed, start over.

9. What's left: The GFCI has failed.

10. Dry out that circuit (F). Fixed → done. Not fixed → go to 11. Can't do it → go to 11.

Careful: Live electricity.

  • Unplug everything on that circuit.
  • Turn its breaker off, C.
  • Plug a lamp into the outlet and turn it on, to see that the power is off. Then unplug it.
  • Wipe the outside of each outlet dry.
  • Leave the circuit off until everything is completely dry.
  • Turn the breaker on and reset the GFCI, F.

11. What's left: That didn't fix it, and nothing else on this list fits what you found. If anything has changed, start over.

If it: The whole house is dead

1. Is there water, smoke or sparks near it, a smell of hot insulation, or has anyone felt a shock? There's water on the floor, or it has been wet or flooded → go to 2. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock → go to 3. No. It's dry, and none of that → go to 4.

  • Look at the floor where you would stand. Water that belongs there, like a sump pit, doesn't count. Water over the floor does.
  • Look and sniff around it, without touching it.
  • Ask if anyone felt a shock from it, even a mild tingle.

2. Stop. There's water on the floor, or it has been wet or flooded

3. Stop. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock

4. Is the main breaker off or tripped? It's off, or it sits short of on → go to 5. It's on → go to 6.

Careful: Live electricity.

  • Stand on a dry spot, with dry hands.
  • Open the panel door, A. Leave the cover behind it on.
  • Look at the main, B.

5. Turn the main back on (B). Fixed → done. Not fixed → go to 7. Can't do it → go to 7.

Careful: Live electricity.

  • Stand on a dry spot, with dry hands.
  • Open the panel door, A. Leave the cover behind it on.
  • Turn the main, B, on as the entry above says.
  • If it trips again, leave it off.

6. What's left: The power is out on the line, not in your house.

7. What's left: Part of what feeds the panel has been lost.

If it: Half the house is dead, or the lights dim and flicker

1. Is there water, smoke or sparks near it, a smell of hot insulation, or has anyone felt a shock? There's water on the floor, or it has been wet or flooded → go to 2. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock → go to 3. No. It's dry, and none of that → go to 4.

  • Look at the floor where you would stand. Water that belongs there, like a sump pit, doesn't count. Water over the floor does.
  • Look and sniff around it, without touching it.
  • Ask if anyone felt a shock from it, even a mild tingle.

2. Stop. There's water on the floor, or it has been wet or flooded

3. Stop. Smoke, sparks, a hot-insulation smell, a plate too hot to touch, or a shock

4. What's left: Part of what feeds the panel has been lost · A bad contact where the power line meets the house.

How to get by

Sources

  • CPSC Guide to Home Wiring Hazards (Publication 518), pp. 5, 8-14, 21, 34
  • Home Electrical Safety Checklist (Publication 513), pp. 6, 7, 14 and 15 [inferred]
  • CPSC Fact Sheet: What Is a GFCI? (Publication 099), p. 2
  • Preventing Home Fires: Arc Fault Circuit Interrupters (AFCIs) (Publication 5133), Should You Install AFCIs?, last paragraph
  • TM 5-683 / NAVFAC MO-116 / AFJMAN 32-1083, Facilities Engineering: Electrical Interior Facilities, para 5-3 c, p. 5-7
  • Construction Electrician Basic (NAVEDTRA 14026), pp. 5-36, 5-38
  • Safety Guidelines: Reentering Your Flooded Home, When you first reenter your home

Open it in Minuteman. In the app it works with no signal.