Household system
Well pump on backup power
Runs the electric well pump you already have from a generator, or from batteries and an inverter, through a switch an electrician installs, to fill your stored water in short runs.
What it gives you
| Which way fits your well | What fits |
|---|---|
| A drilled well. Water within the limit below. An electric pump in the casing. | Well hand pump, beside the electric pump where there is room. Well pump on backup power. DC solar well pump. |
| A drilled well. Water deeper than the limit below. An electric pump in the casing. | Well hand pump or Homemade well pump, beside the electric pump or in its place. Well pump on backup power. DC solar well pump. |
| A drilled well. Water within the limit below. Nothing in the casing. | Well hand pump. Well bucket and windlass. DC solar well pump. Rope pump, in a wide casing. |
| A drilled well. Water deeper than the limit below. Nothing in the casing. | Well hand pump or Homemade well pump. Well bucket and windlass. DC solar well pump. Rope pump, in a wide casing. |
| A driven well (a sand point). Water within the limit below. | Well hand pump, standing on top of the pipe. |
| A driven well (a sand point). Water deeper than the limit below. | Homemade well pump, or a Well hand pump whose maker builds it for a narrow pipe. |
| A dug well. Water within the limit below. Nothing in it. | Well bucket and windlass. Rope pump. Well hand pump. |
| A dug well. Water deeper than the limit below. Nothing in it. | Well bucket and windlass. Rope pump. |
| A dug well with an electric pump in it, at either water level. | Well pump on backup power. Well hand pump, where its pipe has room beside the other. |
| A flowing well, where the water rises to the top unaided. | No pump. Keep it capped and clean, as the wellhead entry on this page says. |
Find your row by the kind of well, how far down its water stands and what is in it now. The second column names the pages that fit, and the links below open them. The entry under the links gives the limit the rows speak of.
Your well already has a pump that works. What it lacks in an outage is power. This page gives it power from a generator, or from a battery bank and an inverter, so the taps run again without anything being changed down the well.
A well pump is wired into the house, so the power reaches it only through a transfer switch or an interlock that a licensed electrician installs. That part is never yours to do, and nothing on this page works without it.
You do not run it all day. One short run fills the pressure tank and your stored-water drums from the tap, and the household draws from the drums until the next run. A generator then burns minutes of fuel a day, and a battery bank lasts.
A windmill pump lifts well water with no electricity at all. Its tower, its size and its cost put it beyond most households, and this page does not build one: a pump maker and a licensed well contractor are the people to ask.
Watch for
Parts
| Parts | Grid up | Salvage |
|---|---|---|
| Transfer switch (installed) | A transfer switch or interlock and an outdoor inlet, chosen for your panel, your pump and your source, and installed by a licensed electrician Sold at: Electrical supply house | Buy new. The electrician chooses it and fits it, and it is the only way any source joins the house's wiring. |
| Portable gasoline generator | A portable generator able to start your pump, with an outlet at the pump's own voltage, sized from the pump's figures by its seller, with its manual Sold at: Hardware store, Farm supply store, Electrical supply house | Look for it in: a working portable generator from your own home or a neighbor's; a generator a small-engine shop has repaired and will part with Where one turns up: Your own home, garage or shed · It is yours; Neighbours, free listings · It is given to you; Appliance, electronics or small-engine shops · Asked for from their discards Before you trust it: Its label must show an outlet at your pump's voltage and enough power for the start. It starts, runs steadily and carries a load. Pass on one that leaks or smells of fuel. If it sat with gas in it, a shop sees it first. |
| Heavy-duty outdoor-rated cord | The generator cord the electrician names for the inlet, rated for what it will carry, as the cord entry says, and long enough to reach from where the generator stands Sold at: Hardware store, Electrical supply house | Look for it in: a generator cord from your own garage or a neighbor's Where one turns up: Your own home, garage or shed · It is yours; Neighbours, free listings · It is given to you Before you trust it: It must fit the inlet and the generator's outlet as made, with its rating printed on the jacket. Pass on any with a cut, a nick, a taped repair or a scorched plug. Never an adapter. |
| Battery CO alarm | Battery CO alarms, or plug-in ones with a battery backup, each with a test button and its date on the back Sold at: Hardware store, Electrical supply house | Buy new. An alarm past its date or of unknown history is not an alarm. |
| Approved fuel can | Approved safety cans made for gasoline and labelled for it Sold at: Hardware store, Auto parts store, Farm supply store | Look for it in: a gasoline can from your own garage or shed Where one turns up: Your own home, garage or shed · It is yours; Neighbours, free listings · It is given to you Before you trust it: Only a can made and labelled for gasoline, never one that held anything else. No crack, split seam or rust, and its cap, spout and vent all seal. Check it outdoors, empty. |
| DC–AC inverter | For the battery route: a pure sine wave inverter able to start your pump at the pump's own voltage, sized from the pump's figures by its seller, with its manual Sold at: Solar retailer, RV and marine supply, Electrical supply house | Buy new. It has to start a motor that asks for several times its running power. A used inverter's real strength, and what it has been through, are unknown until the pump stalls on it. |
| 12 V deep-cycle battery | For the battery route: batteries their label calls deep-cycle, all of one type and one age, in the bank the inverter's manual asks for Sold at: Solar retailer, RV and marine supply, Auto parts store | Look for it in: computer backup power units; RV and boat house batteries Where one turns up: Appliance, electronics or small-engine shops · Asked for from their discards; Neighbours, free listings · It is given to you; Your own home, garage or shed · It is yours Before you trust it: Read the label for its exact type. Build a bank from batteries of one age and one type only. Pass on any that smells, has changed color or shape, runs hot, leaks or makes odd noises. |
| Fuse / fuse block | For the battery route: a fuse holder for the lead at the battery, and fuses of the rating the inverter's manual names Sold at: Auto parts store, RV and marine supply, Electrical supply house | Look for it in: RV and boat battery setups being replaced Where one turns up: Neighbours, free listings · It is given to you; Your own home, garage or shed · It is yours Before you trust it: Keep the holder only if its body is uncracked and unscorched. Fit a new fuse of the rating the inverter's manual names, whatever fuse it came with. |
Salvage from what's yours, what's given to you, or what you buy as scrap.
Tools
- Multimeter
- Bound notebook and pencils
- Permanent marker
- Work gloves
- Safety glasses
Build it
- Find your pump's figures and write them in the well folder: which household voltage it runs on, and its running amps or watts. They are on the pump's control box, on its breaker's label, or in the well's papers.
- Worth knowing Most well pumps run on the higher household voltage, the one an electric clothes dryer uses. Many small generators and inverters give only the lower one, and they cannot run such a pump at all.
- Running power is not the figure that decides. The entry below says why, and what the source has to carry.
- Take the pump's figures to whoever sells the generator or the inverter, and ask them plainly whether it will start this pump. If they can't say, ask the pump's maker for its starting figure.
- A soft-start fitting can lower what the pump asks for at the start. Whether your pump can take one is its maker's answer, and fitting it is the electrician's work.
- Do not skip this Have a licensed electrician install the transfer switch or interlock and the inlet, as the first two entries at the top of this page say. Tell them the well pump is the load that has to start, and give them its figures.
- Do not skip this Never join a generator or an inverter to the house any other way: not through a wall outlet, not at the panel, and not at the pump's own wires.
- Ask the electrician to show everyone in the house the order of the switches, and write it on a card kept at the panel.
- Do not skip this The generator route. Stand the generator outdoors where its entry at the top of this page says, with CO alarms in the house as theirs says. The Generator station page builds its pad, its chain and its fuel store.
- Run its cord to the inlet the electrician fitted, and nowhere else. The cord is the one the electrician named, rated as the entry below says.
- Worth knowing Stop the generator and let it cool before you add fuel, as the entry below says. The pump can wait.
- The battery route. The bank and the inverter stand where the battery entry below says, and feed the same inlet or switch the electrician fitted. It costs more than a generator that can do the same job, and it runs with no fuel and no fumes.
- Worth knowing Fit the fuse at the battery and make the connections in the order the second entry below gives. Where the inverter's manual and the electrician say otherwise, theirs is the answer.
- Keep the bank charged while the grid is up, with the charger its maker names, so it is full on the day the power goes.
- Run the pump in batches. Switch off every other large load first, so the source has only the pump to start.
- Bring the source up, move the switches in the order on the card, and let the pump fill the pressure tank.
- While it runs, fill your stored-water drums from the tap, as the Stored-water tanks page shows. Then shut the pump's breaker off, and shut the source down.
- Draw the day's water from the drums. Run the pump again when they are low, not when a tap is merely dry.
If you salvaged the parts. A salvaged generator joins the build only once it has passed its check in the parts list, and only through the electrician's switch. The switch, the inverter and the CO alarms are bought new on both routes.
How you know it works
It works when every line below is true.
- A licensed electrician installed the switch or interlock and the inlet, and their paper for it is in the well folder.
- On a day the grid is up, with the main off as the switch entry says, the source started the pump and the pump filled the pressure tank.
- The generator stood where its entry says for that test, and the CO alarms in the house were tested the same day.
- The card at the panel gives the order of the switches, and everyone who may run the pump has done it once.
- The stored-water drums were filled during the test run.
Upkeep
- Run the whole test again each season, so the day it matters is not the first time in a year.
- Keep the generator as its manual says, with fresh fuel stored as the Generator station page shows. Keep a battery bank charged and its terminals clean.
- Test the CO alarms when you test the pump.
- If the source starts the pump and it stalls, or a breaker trips, stop. Do not try a bigger breaker or a second source: call the electrician.
- If the pump itself fails and is pulled or replaced, that work opens the well, and the entry below applies.
Feeds
Sources
- Ready.gov / FEMA · Power Outages (Jun 2026) + FEMA public guidance
- CPSC · CPSC Safety Alert: Portable Generator Hazards (Publication 5123, 10/2021)
- OSHA (U.S. Department of Labor) · Using Portable Generators Safely (Fact Sheet, DTSEM FS-3286, 09/2005)
- CDC
- Washington State Dept. of Health · Generator Use During a Power Outage
- NFPA · NFPA 70 National Electrical Code, Art. 690 (PV) and 706 (energy storage)
- OSHA (U.S. Department of Labor) · 29 CFR 1926.441 — Batteries and battery charging
- Trojan Battery Company (manufacturer) · Battery Maintenance
- North Dakota State University Extension · Safely use standby generators for emergency power (news release, December 2022)
- Alabama Cooperative Extension System · Standby Generators for Emergency Power (Emergency Handbook, December 11, 2018)
- EPA (Private Drinking Water Wells) · Protect Your Home's Water (last updated February 26, 2026)
Open it in Minuteman. In the app it works with no signal.