What it gives you
A solar station makes its own electricity every sunny day and stores it for the night. Sized to what your household can't do without, it keeps lights, phones, a radio and a small pump or fan going when the grid is down, with no fuel to buy and nothing to run outdoors.
How big to build it is a question of arithmetic. List your loads and run them through the power budget calculator before you buy anything.
Watch for
Parts
| Parts | Grid up | Salvage |
|---|---|---|
| Solar panel | Rigid solar panels with a label giving their voltage and current Sold at: Solar retailer, RV and marine supply, Electrical supply house | Look for it in: panels pulled in a re-roof; RV and boat solar kits being replaced Where one turns up: Construction and renovation sites · Asked for, taken only with a yes; Building-material reuse store · Bought; Neighbours, free listings · It is given to you Before you trust it: Pass on a panel with cracked glass or a scorched junction box. Read its label, and check its leads for polarity with a multimeter before it goes near the controller. |
| Solar charge controller | Solar charge controller rated for the panels' current, with a setting for your battery's chemistry Sold at: Solar retailer, RV and marine supply | Look for it in: RV and boat solar kits being replaced Where one turns up: Neighbours, free listings · It is given to you; Building-material reuse store · Bought Before you trust it: Find its manual, confirm it has a setting for your battery's chemistry, and confirm its ratings cover your panels. Without the manual, leave it. |
| 12 V deep-cycle battery | Certified deep-cycle battery, lithium iron phosphate or sealed lead-acid, at the controller's system voltage Sold at: Solar retailer, RV and marine supply, Auto parts store | Look for it in: computer backup power units (UPS); RV and boat house batteries Where one turns up: Appliance, electronics or small-engine shops · Asked for from their discards; Neighbours, free listings · It is given to you; Your own home, garage or shed · It is yours Before you trust it: Read the label for its exact type: sealed, gel or flooded. Build a bank from batteries of one age and one type only. Pass on any that smells, has changed color or shape, runs hot, leaks or makes odd noises. |
| Fuse / fuse block | Fuse holder and fuses for each lead, sized to the wire from the wire table Sold at: Electrical supply house, RV and marine supply, Auto parts store | Look for it in: RV and boat battery setups being replaced Where one turns up: Neighbours, free listings · It is given to you; Your own home, garage or shed · It is yours Before you trust it: Keep the holder only if its body is uncracked and unscorched. Fit a new fuse sized to your wire, whatever fuse it came with. |
| 12 V wiring & lugs | Stranded copper battery and panel cable with crimped lugs, the gauge chosen from the wire table Sold at: RV and marine supply, Electrical supply house, Auto parts store | Look for it in: battery cables from scrapped cars; RV wiring being replaced Where one turns up: Pull-your-own auto salvage yard · Bought at the yard's price; Neighbours, free listings · It is given to you Before you trust it: Cut back to bright copper. Pass on any length with cracked insulation or green corrosion under the jacket. |
| DC–AC inverter | Pure sine wave inverter sized to the AC loads you will run Sold at: Solar retailer, RV and marine supply, Auto parts store | Look for it in: RV inverters replaced in an upgrade Where one turns up: Neighbours, free listings · It is given to you; Building-material reuse store · Bought Before you trust it: Find its manual, and pass on one with a scorched case or a burnt smell. Without its manual, leave it. It gets its own lead and its own fuse at the battery, like every other lead. |
| Dimensional lumber | Rot-resistant lumber and outdoor screws for a panel frame Sold at: Lumber yard, Hardware store | Look for it in: framing lumber left over from a renovation Where one turns up: Construction and renovation sites · Asked for, taken only with a yes; Building-material reuse store · Bought; Your own home, garage or shed · It is yours Before you trust it: Pass on boards that are rotten, split or soft at the ends. |
Salvage from what's yours, what's given to you, or what you buy as scrap.
Tools
- Multimeter
- Adjustable wrench
- Drill/driver and bits
- PPE — helmet, gloves, boots, eyewear
Build it
- If you have never wired a battery to a panel, build the small station in the field guide first. Everything below is the same order, only bigger.
- Worth knowing Build the panel frame and fix the panels to it where they get sun most of the day, clear of shade. Cover them, or turn them face down, as soon as they're up.
- Do not skip this Set the battery bank where the battery entries above allow it to live, away from where you sleep and anything that burns.
- Do not skip this Take every fuse out of its holder, and keep them out until a step says to fit one.
- Do not skip this Join the batteries into one bank, and the panels into one array, the way the controller's and the battery's manuals direct. Wiring them in series or in parallel sets the system voltage, and it must be one the controller takes. Fuse each connection as the manuals direct.
- Do not skip this Mount the main fuse holder on the bank's positive terminal, as close to it as it will go.
- Worth knowing Run red wire from the fuse holder toward the controller, and black from the battery negative. Don't connect them yet, and keep the bare ends apart.
- Worth knowing Fit the main fuse and read the two loose ends with the multimeter. The reading should be positive; a minus sign means they are swapped.
- Do not skip this Pull the fuse. Connect the leads to the controller's battery terminals, red to positive, tighten each lug and tug it, then fit the fuse. The controller should wake up and show the battery.
- Set the controller to your battery's chemistry, following its manual.
If you salvaged the parts. A salvaged bank is usually lead-acid rather than lithium. Set the controller to the exact type on its label: sealed, gel or flooded. Give the bank the ventilation the lead-acid entry above asks for, and never mix a new battery in with older ones.
- Do not skip this Uncover the panels just long enough to check their leads with the multimeter, leads apart. Cover them again, then connect them to the controller's panel terminals. Never connect a panel straight to the battery.
- Uncover the panels. The controller should show that it is charging.
- Do not skip this Wire the inverter to the battery on its own lead, with its own fuse at the battery end, and check its polarity before you fit that fuse.
- Do not skip this Plug your AC loads into the inverter's own outlets. Never plug the inverter into a wall outlet or wire it into the house panel.
If you salvaged the parts. A salvaged controller or inverter follows its own manual where the manual gives a different order. A unit with no manual is not worth the guess.
How you know it works
It works when every line below is true.
- The controller shows the battery, and its reading agrees with the multimeter at the terminals.
- In sun, the controller shows the panels charging.
- Every lead that touches the battery has a fuse at the battery end.
- The inverter runs a small lamp from its own outlet.
- Nothing gets warm at a lug or fuse holder when the loads you planned are running.
Then run your planned loads for a full day and night, and compare what is left in the morning with what the calculator told you.
Upkeep
- Each month, look over every lug, terminal and fuse holder for heat marks, corrosion or looseness, with the panels covered and the main fuse out.
- Clear dust, leaves and snow off the panels when they build up.
- Keep the battery space's ventilation clear and nothing stored against the bank.
- Watch the batteries for the warning signs in the lithium entry above, and retire any battery that shows one.
- After a storm, check the panel frame and every cable run for damage.
Start smaller
A Hundred Watts of Sunlight
Feeds
Sources
- NFPA · NFPA 70 National Electrical Code, Art. 690 (PV) and 706 (energy storage)
- Florida Solar Energy Center (University of Central Florida) · Charge-controller field testing (FSEC)
- Charge-controller manufacturers · Controller manufacturer instructions/manuals
- DOE/EERE · Basics of a Solar Electric System (DOE/GO-102002-1593)
- OSHA (U.S. Department of Labor) · 29 CFR 1926.441 — Batteries and battery charging
- Trojan Battery Company (manufacturer) · Battery Maintenance
- US Fire Administration (FEMA) · Battery Fire Safety
- South Carolina Office of Regulatory Staff, Energy Office · Grid-Connected (Solar: select a system)
- Ready.gov / FEMA · Power Outages (Jun 2026) + FEMA public guidance
- Washington State Dept. of Health · Generator Use During a Power Outage
- DOE (Energy Saver) · Estimating Appliance and Home Electronic Energy Use
- Virginia Tech Extension · Estimating Appliance and Home Electronic Energy Use (Virginia Cooperative Extension, 2901-9014)
Open it in Minuteman. In the app it works with no signal.