Household system
Compost heat mound
A big, damp mound of wood chips with a coil of tubing buried in it, whose slow heat is carried by a buried line to a radiator in one warm room or a greenhouse.
What it gives you
Wood chips heap up, stay damp and rot, and a big pile of them stays warm inside for months. A coil of tubing buried in the pile takes some of that warmth, and water carries it through a buried, insulated line to a radiator in the one warm room, or to a greenhouse.
Expect modest heat. It is warm water, not a furnace, and the first entry at the top of this page says what one careful trial found. It helps a room the household already keeps warm; it does not heat a house.
This page builds the pile, the coil and the line to the building's wall. Everything from the wall in, the pump, the antifreeze, the relief valve, the radiator and the pressure test, is a licensed heating contractor's or plumber's job, and is not in this page's cost.
Watch for
Parts
| Parts | Grid up | Salvage |
|---|---|---|
| Wood chip mulch | Fresh wood chips by the truckload, from untreated, unpainted wood, chipped from whole branches with their leaves Sold at: Garden center, Farm supply store, Lumber yard | Look for it in: a tree crew's load of fresh chips, dropped where you ask; the town's free mulch pile Where one turns up: Restaurants, bakeries, woodshops, loading docks · Asked for, taken only with a yes; Neighbours, free listings · It is given to you; Transfer station / dump reuse area · Taken where the site allows it Before you trust it: Ask what was chipped. Pass on any load with painted or treated wood, boards, plastic or trash in it, and on chips from trees that were sprayed or sick. |
| Straw or hay bales | Straw or hay bales, tight and dry Sold at: Farm supply store, Feed store, Garden center | Look for it in: last season's bales; spoiled for feed but still tied Where one turns up: Farm auctions, farm supply culls · Bought or given; Neighbours, free listings · It is given to you Before you trust it: The strings hold when you lift it, and it is not black or slimy inside. |
| Tubing for a buried heat coil | A roll of tubing made for hot-water heating, rated by its maker for the loop's heat and pressure and for burial, long enough for the coil and both lines to the wall Sold at: Plumbing supply house, Farm supply store | Look for it in: a leftover roll from a heated-floor job; still in its wrap Where one turns up: Construction and renovation sites · Asked for, taken only with a yes; Neighbours, free listings · It is given to you; Building-material reuse store · Bought Before you trust it: Its rating is printed along its length and can be read, and the contractor who will test it says it will do. No kink, cut or flattened place. Never a garden hose or irrigation pipe with no rating. |
| Wire coil frame and posts | Welded wire fencing and steel fence posts, to stand the coil on Sold at: Farm supply store, Hardware store | Look for it in: a roll of old welded wire fencing and steel posts from a fence taken down Where one turns up: Farm auctions, farm supply culls · Bought or given; Neighbours, free listings · It is given to you; Your own home, garage or shed · It is yours Before you trust it: No rusted-through wire, and posts straight enough to drive. |
| PVC pipe & fittings | Wide plastic drain pipe, for burial, to carry both insulated lines from the pile to the wall Sold at: Plumbing supply house, Hardware store | Look for it in: offcuts of wide drain pipe from a building job Where one turns up: Construction and renovation sites · Asked for, taken only with a yes; Building-material reuse store · Bought; Neighbours, free listings · It is given to you Before you trust it: No crack or crushed section; it must stay open under the soil. |
| Foam pipe insulation sleeves | Foam insulation sleeves sized to the tubing, for both lines, end to end Sold at: Hardware store, Plumbing supply house | Look for it in: unused foam sleeves left from a plumbing job Where one turns up: Construction and renovation sites · Asked for, taken only with a yes; Your own home, garage or shed · It is yours; Neighbours, free listings · It is given to you Before you trust it: Whole sleeves with no crushed or split stretch. |
| Compost thermometer (long stem) | A compost thermometer with the longest stem you can find, to reach the middle of the pile Sold at: Garden center, Farm supply store, Hardware store | Look for it in: a long compost thermometer from your own shed or a gardener's Where one turns up: Your own home, garage or shed · It is yours; Neighbours, free listings · It is given to you Before you trust it: Stand it in a pot of hot water beside a thermometer you trust; the two should agree. Pass on one with a cracked face or a bent stem. |
| N95/P100 respirators | Respirators approved by NIOSH, N95 or better, in sizes that seal on each face Sold at: Hardware store | Buy new. A respirator that has been worn, stored loose or lost its seal does not protect. |
| Tarp | A tarp to keep a heavy rain off the cap Sold at: Hardware store, Farm supply store | Look for it in: a tarp from your own garage or a neighbor's Where one turns up: Your own home, garage or shed · It is yours; Neighbours, free listings · It is given to you Before you trust it: No tear wider than a hand, and edges strong enough to tie down in wind. |
Salvage from what's yours, what's given to you, or what you buy as scrap.
Tools
- Folding shovel
- Wheelbarrow
- Garden fork
- Garden hose section
- Work gloves
- Safety glasses
- Tape measure
- Pliers (channel-lock)
Build it
- Worth knowing Before you start, find the heating contractor or plumber who will fit the inside and test the coil, and ask the building department whether the loop needs a permit, as the entry below says. If nobody will fit the inside, build nothing past this step.
- Pick level ground that drains, near the building it will warm but never against a wall: leave room to walk all round the pile, and set it where a hose reaches every side of it.
- Worth knowing Have the lines under the ground marked before you dig, as the entry below says, then dig a trench from the pile's place to the wall.
- Cut two lengths of tubing to run from the middle of the pile's place to the wall, and label one hot and one cold at both ends before anything goes in the trench.
- Sleeve both lines in foam end to end, pull them together through the wide pipe, and lay it in the trench. Bury and insulate both lines, as the entry below says, and cap their ends at the wall for the contractor.
- Ring the pile's place with bales, leaving a gap where the lines come in. Spread a bed of chips inside the ring.
- Stand the wire fencing in a tall cylinder in the middle and drive the posts through it. Tie the coil to it in a spiral, the cold line in at the foot and the hot line out at the top, so the pile's settling bears on the frame and not on the tubing.
If you salvaged the parts. A salvaged roll goes into the coil only once the contractor has read its printed rating and said it will do.
- Do not skip this No chip goes over the coil until the contractor has joined it to the lines, filled it and pressure-tested it. Once it is buried, nobody can reach it again until the pile comes down.
- Worth knowing Put on gloves and a respirator, as the entry below says, and keep anyone it names away while you work.
- Build the pile round and over the coil a layer at a time, wetting each layer as you go, as the entry below says. Mix in greens as the hot compost entry names them: garden trimmings and grass.
- Do not skip this No manure goes in this pile, from any animal. The coop and the hutch send theirs to the three-bin hot compost. What the hot compost entry keeps out stays out here too.
- Lay a hose under the top layer, its end out where you can reach it, so the pile can be wetted again without opening it. The pile is never turned.
- Cap it with leaves or loose hay, and keep a tarp by to pull over it in a heavy rain.
- Push the thermometer into the middle of the pile each day, and write the date and the reading in a notebook kept in a dry box by the pile.
- Do not skip this Watch for what the fire entry below names, and do what it says. Never climb on the pile.
- Have the contractor start the pump only once the pile's middle is hot, as the method entry says. If the pile cools after the pump starts, ask for a slower flow.
How you know it works
It works when the pile's middle climbs on the thermometer over its first days and holds there, and, once the pump runs, the radiator is warm to the hand and the pile's reading does not fall away. If the pile stays cold, it is too dry or short of greens. If the radiator stays cold while the pile is hot, the contractor checks the flow and the line.
Upkeep
- Read the thermometer every day, and write it down.
- When the pile dries, wet it through the hose under the cap until it is damp, not dripping.
- Top up the cap as the pile settles.
- The contractor checks the loop's pressure and its antifreeze before each winter.
- When the heat fades for good, have the contractor drain the loop before the pile comes down.
- Take the pile down damp, in respirators, and look over the coil; a kinked or flattened run is cut out before it is used again.
- Spread what is left where food does not grow, round shrubs and trees you do not eat from.
- Before any of it goes where food grows, read the entry below, with the notebook in hand.
Feeds
Sources
- USDA Natural Resources Conservation Service · National Engineering Handbook, Part 637 Environmental Engineering, Chapter 2, Composting (210-VI-NEH, Amend. 40, November 2010)
- Compost Science & Utilization (Taylor & Francis), open access · Smith, Aber and Rynk (2017), Heat Recovery from Composting: A Comprehensive Review of System Design, Recovery Rate, and Utilization, 25:sup1, S11-S22, doi 10.1080/1065657X.2016.1233082
- USDA SARE (Western SARE), farmer/rancher grant report by Sunspot Urban Farm · Supplemental Heating of High Tunnels by Energy-Producing Compost Piles, final report for FW15-057 (Fort Collins, CO; project end 2018)
- Cornell Small Farms Program (Small Farms Quarterly) · Compost Power! (Sam Gorton, October 1, 2012)
- Northeast Regional Agricultural Engineering Service (NRAES), Cooperative Extension · On-Farm Composting Handbook (NRAES-54, June 1992), ed. Robert Rynk
- USDA Natural Resources Conservation Service · Conservation Practice Standard, Composting Facility, Code 317 (NHCP, September 2020)
- Alberta Agriculture, Food and Rural Development (Government of Alberta, Canada) · Fire - Compost and Organic Matter (Agdex 086-9, April 2006)
- Massachusetts Department of Fire Services · Mulch Fire Safety (web page) and Preventing Mulch Fires (flyer, 5/23)
- CDC (National Center for Emerging and Zoonotic Infectious Diseases) · Reducing Risk for Aspergillosis
- CDC (National Center for Emerging and Zoonotic Infectious Diseases) · About Aspergillosis
- NIOSH (CDC) · NIOSH Update: NIOSH Warns of Agricultural Hazards (July 19, 1994), on organic dust toxic syndrome
- International Code Council · 2024 International Residential Code: R105 Permits; Chapter 20 Boilers and Water Heaters; Chapter 21 Hydronic Piping; Section P2902 Protection of Potable Water Supply
- International Code Council · 2024 International Residential Code, Chapter 23, Section M2301 Solar Thermal Energy Systems
- Agency for Toxic Substances and Disease Registry (CDC) · ToxFAQs: Ethylene Glycol (June 2013)
- Agency for Toxic Substances and Disease Registry (CDC) · ToxFAQs: Propylene Glycol (September 1997)
- EPA · Composting At Home
Open it in Minuteman. In the app it works with no signal.